» Articles » PMID: 38430228

Contact Lens Fitting and Changes in the Tear Film Dynamics: Mathematical and Computational Models Review

Overview
Specialty Ophthalmology
Date 2024 Mar 2
PMID 38430228
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: This review explores mathematical models, blinking characterization, and non-invasive techniques to enhance understanding and refine clinical interventions for ocular conditions, particularly for contact lens wear.

Methods: The review evaluates mathematical models in tear film dynamics and their limitations, discusses contact lens wear models, and highlights computational mechanical models. It also explores computational techniques, customization of models based on individual blinking dynamics, and non-invasive diagnostic tools like high-speed cameras and advanced imaging technologies.

Results: Mathematical models provide insights into tear film dynamics but face challenges due to simplifications. Contact lens wear models reveal complex ocular physiology and design aspects, aiding in lens development. Computational mechanical models explore eye biomechanics, often integrating tear film dynamics into a Multiphysics framework. While different computational techniques have their advantages and disadvantages, non-invasive tools like OCT and thermal imaging play a crucial role in customizing these Multiphysics models, particularly for contact lens wearers.

Conclusion: Recent advancements in mathematical modeling and non-invasive tools have revolutionized ocular health research, enabling personalized approaches. The review underscores the importance of interdisciplinary exploration in the Multiphysics approach involving tear film dynamics and biomechanics for contact lens wearers, promoting advancements in eye care and broader ocular health research.

Citing Articles

Influence of Contact Lens Parameters on Cornea: Biomechanical Analysis.

Ramasubramanian D, Hernandez-Verdejo J, Lopez-Alonso J Bioengineering (Basel). 2024; 11(10).

PMID: 39451343 PMC: 11505363. DOI: 10.3390/bioengineering11100966.

References
1.
Messmer E . The pathophysiology, diagnosis, and treatment of dry eye disease. Dtsch Arztebl Int. 2015; 112(5):71-81. PMC: 4335585. DOI: 10.3238/arztebl.2015.0071. View

2.
Wang S, Hatami-Marbini H . Constitutive Modeling of Corneal Tissue: Influence of Three-Dimensional Collagen Fiber Microstructure. J Biomech Eng. 2020; 143(3). DOI: 10.1115/1.4048401. View

3.
Garhofer G, Aranha Dos Santos V, Stegmann H, Schmidl D, Adzhemian N, Werkmeister R . The Association between Tear Film Thickness as Measured with OCT and Symptoms and Signs of Dry Eye Disease: A Pooled Analysis of 6 Clinical Trials. J Clin Med. 2020; 9(11). PMC: 7700265. DOI: 10.3390/jcm9113791. View

4.
Wong , Fatt I , Radke . Deposition and Thinning of the Human Tear Film. J Colloid Interface Sci. 1996; 184(1):44-51. DOI: 10.1006/jcis.1996.0595. View

5.
Moore J, Lopes B, Eliasy A, Geraghty B, Wu R, White L . Simulation of the Effect of Material Properties on Soft Contact Lens On-Eye Power. Bioengineering (Basel). 2019; 6(4). PMC: 6956153. DOI: 10.3390/bioengineering6040094. View