» Articles » PMID: 38416449

Reliability of Measures of Lower-Body Strength and Speed in Academy Male Adolescent Soccer Players

Overview
Specialty Physiology
Date 2024 Feb 28
PMID 38416449
Authors
Affiliations
Soon will be listed here.
Abstract

Ferguson, J, Gibson, NV, Weston, M, and McCunn, R. Reliability of measures of lower body strength and speed in academy male adolescent soccer players. J Strength Cond Res 38(3): e96-e103, 2024-The Nordbord and ForceFrame represent a practical and time efficient means of assessing eccentric hamstring and isometric adductor strength in the large number of squads and players associated with youth soccer academies, yet measurement reliability in this population is unexamined. Therefore, over a period of 4 days, with no less than 24 hours and no more than 48 hours between trials, 37 players (age: 14.7 ± 0.8 years, stature: 168.7 ± 7.8 cm, mass: 57.7 ± 9.1 kg, and maturity offset: 0.8 ± 0.9 years) were assessed for eccentric hamstring strength (force, torque), isometric adductor strength (long and short lever positions), and 30-m sprint (5, 10, and 20-m splits), using the Nordbord, ForceFrame, and electronic timing gates, respectively, on 3 separate occasions. Relative reliability (intraclass correlation coefficient) was rated as good for all Nordbord (range: 0.86-0.89) and ForceFrame (0.78-0.85) measures and ranged from moderate (0.53) to excellent (0.93) for the speed measures, improving with increased distance. Absolute reliability (standard error of the measurement [%SEM]) ranged from 7 to 8% (Nordbord), 3 to 11% (ForceFrame), and 1 to 4% (sprints). Our data provide the first Nordbord and ForceFrame reliability estimates in adolescent soccer academy players. To interpret test sensitivity, practitioners are encouraged to interpret our estimates of absolute reliability against meaningful change values derived from personal experience and evidence-based knowledge and not against absolute or standardized thresholds.

Citing Articles

Distributed Wearable Ultrasound Sensors Predict Isometric Ground Reaction Force.

King E, Patwardhan S, Bashatah A, Magee M, Jones M, Wei Q Sensors (Basel). 2024; 24(15).

PMID: 39124070 PMC: 11314925. DOI: 10.3390/s24155023.


Between-Session Reliability of Athletic Performance and Injury Mitigation Measures in Female Adolescent Athletes in the United States.

Franklin E, Stebbings G, Morse C, Runacres A, DosSantos T Life (Basel). 2024; 14(7).

PMID: 39063645 PMC: 11278427. DOI: 10.3390/life14070892.

References
1.
Rumpf M, Cronin J, Oliver J, Hughes M . Assessing youth sprint ability-methodological issues, reliability and performance data. Pediatr Exerc Sci. 2011; 23(4):442-67. DOI: 10.1123/pes.23.4.442. View

2.
Lindberg K, Solberg P, Bjornsen T, Helland C, Ronnestad B, Thorsen Frank M . Strength and Power Testing of Athletes: A Multicenter Study of Test-Retest Reliability. Int J Sports Physiol Perform. 2022; 17(7):1103-1110. DOI: 10.1123/ijspp.2021-0558. View

3.
Williams A, Reilly T . Talent identification and development in soccer. J Sports Sci. 2000; 18(9):657-67. DOI: 10.1080/02640410050120041. View

4.
Opar D, Piatkowski T, Williams M, Shield A . A novel device using the Nordic hamstring exercise to assess eccentric knee flexor strength: a reliability and retrospective injury study. J Orthop Sports Phys Ther. 2013; 43(9):636-40. DOI: 10.2519/jospt.2013.4837. View

5.
Dugdale J, Arthur C, Sanders D, Hunter A . Reliability and validity of field-based fitness tests in youth soccer players. Eur J Sport Sci. 2018; 19(6):745-756. DOI: 10.1080/17461391.2018.1556739. View