A High Respiratory Drive Is Associated with Weaning Failure in Patients with COVID-19-Associated Acute Respiratory Distress Syndrome: The Role of the Electrical Activity of the Diaphragm

Overview
Journal J Clin Med
Specialty General Medicine
Date 2024 Feb 24
PMID 38398433
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Mechanical ventilation is the main supportive treatment of severe cases of COVID-19-associated ARDS (C-ARDS). Weaning failure is common and associated with worse outcomes. We investigated the role of respiratory drive, assessed by monitoring the electrical activity of the diaphragm (EAdi), as a predictor of weaning failure.

Methods: Consecutive, mechanically ventilated patients admitted to the ICU for C-ARDS with difficult weaning were enrolled. Blood gas, ventilator, and respiratory mechanic parameters, as well as EAdi, were recorded at the time of placement of EAdi catheter, and then after 1, 2, 3, 7, and 10 days, and compared between patients with weaning success and weaning failure.

Results: Twenty patients were enrolled: age 66 (60-69); 85% males; PaO/FiO at admission 148 (126-177) mmHg. Thirteen subjects (65%) were classified as having a successful weaning. A younger age (OR(95%CI): 0.02 (0.01-0.11) per year), a higher PaO/FiO ratio (OR(95%CI): 1.10 (1.01-1.21) per mmHg), and a lower EAdi (OR(95%CI): 0.16 (0.08-0.34) per μV) were associated with weaning success.

Conclusion: In critically ill patients with moderate-severe C-ARDS and difficult weaning from mechanical ventilation, a successful weaning was associated with a lower age, a higher oxygenation, and a lower respiratory drive, as assessed at the bedside via EAdi monitoring.

References
1.
Funk G, Anders S, Breyer M, Burghuber O, Edelmann G, Heindl W . Incidence and outcome of weaning from mechanical ventilation according to new categories. Eur Respir J. 2009; 35(1):88-94. DOI: 10.1183/09031936.00056909. View

2.
Heyland D, Cook D, Griffith L, Keenan S, Brun-Buisson C . The attributable morbidity and mortality of ventilator-associated pneumonia in the critically ill patient. The Canadian Critical Trials Group. Am J Respir Crit Care Med. 1999; 159(4 Pt 1):1249-56. DOI: 10.1164/ajrccm.159.4.9807050. View

3.
Vallverdu I, Calaf N, Subirana M, Net A, Benito S, Mancebo J . Clinical characteristics, respiratory functional parameters, and outcome of a two-hour T-piece trial in patients weaning from mechanical ventilation. Am J Respir Crit Care Med. 1998; 158(6):1855-62. DOI: 10.1164/ajrccm.158.6.9712135. View

4.
Sinderby C, Beck J, Lindstrom L, Grassino A . Enhancement of signal quality in esophageal recordings of diaphragm EMG. J Appl Physiol (1985). 1997; 82(4):1370-7. DOI: 10.1152/jappl.1997.82.4.1370. View

5.
Silva P, Ball L, Rocco P, Pelosi P . Power to mechanical power to minimize ventilator-induced lung injury?. Intensive Care Med Exp. 2019; 7(Suppl 1):38. PMC: 6658623. DOI: 10.1186/s40635-019-0243-4. View