» Articles » PMID: 38388717

Ultra-low Dose Chest CT with Silver Filter and Deep Learning Reconstruction Significantly Reduces Radiation Dose and Retains Quantitative Information in the Investigation and Monitoring of Lymphangioleiomyomatosis (LAM)

Overview
Journal Eur Radiol
Specialty Radiology
Date 2024 Feb 22
PMID 38388717
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: Frequent CT scans to quantify lung involvement in cystic lung disease increases radiation exposure. Beam shaping energy filters can optimize imaging properties at lower radiation dosages. The aim of this study is to investigate whether use of SilverBeam filter and deep learning reconstruction algorithm allows for reduced radiation dose chest CT scanning in patients with lymphangioleiomyomatosis (LAM).

Material And Methods: In a single-center prospective study, 60 consecutive patients with LAM underwent chest CT at standard and ultra-low radiation doses. Standard dose scan was performed with standard copper filter and ultra-low dose scan was performed with SilverBeam filter. Scans were reconstructed using a soft tissue kernel with deep learning reconstruction (AiCE) technique and using a soft tissue kernel with hybrid iterative reconstruction (AIDR3D). Cyst scores were quantified by semi-automated software. Signal-to-noise ratio (SNR) was calculated for each reconstruction. Data were analyzed by linear correlation, paired t-test, and Bland-Altman plots.

Results: Patients averaged 49.4 years and 100% were female with mean BMI 26.6 ± 6.1 kg/m. Cyst score measured by AiCE reconstruction with SilverBeam filter correlated well with that of AIDR3D reconstruction with standard filter, with a 1.5% difference, and allowed for an 85.5% median radiation dosage reduction (0.33 mSv vs. 2.27 mSv, respectively, p < 0.001). Compared to standard filter with AIDR3D, SNR for SilverBeam AiCE images was slightly lower (3.2 vs. 3.1, respectively, p = 0.005).

Conclusion: SilverBeam filter with deep learning reconstruction reduces radiation dosage of chest CT, while maintaining accuracy of cyst quantification as well as image quality in cystic lung disease.

Clinical Relevance Statement: Radiation dosage from chest CT can be significantly reduced without sacrificing image quality by using silver filter in combination with a deep learning reconstructive algorithm.

Key Points: • Deep learning reconstruction in chest CT had no significant effect on cyst quantification when compared to conventional hybrid iterative reconstruction. • SilverBeam filter reduced radiation dosage by 85.5% compared to standard dose chest CT. • SilverBeam filter in coordination with deep learning reconstruction maintained image quality and diagnostic accuracy for cyst quantification when compared to standard dose CT with hybrid iterative reconstruction.

Citing Articles

Brazilian Thoracic Association recommendations for the management of lymphangioleiomyomatosis.

Baldi B, Feitosa P, Rubin A, Amaral A, Freitas C, Costa C J Bras Pneumol. 2025; 51(1):e20240378.

PMID: 39936727 PMC: 11796567. DOI: 10.36416/1806-3756/e20240378.

References
1.
Xu K, Xu W, Liu S, Yu J, Tian X, Yang Y . Lymphangioleiomyomatosis. Semin Respir Crit Care Med. 2020; 41(2):256-268. DOI: 10.1055/s-0040-1702195. View

2.
McCormack F, Inoue Y, Moss J, Singer L, Strange C, Nakata K . Efficacy and safety of sirolimus in lymphangioleiomyomatosis. N Engl J Med. 2011; 364(17):1595-606. PMC: 3118601. DOI: 10.1056/NEJMoa1100391. View

3.
McCarthy C, Gupta N, Johnson S, Yu J, McCormack F . Lymphangioleiomyomatosis: pathogenesis, clinical features, diagnosis, and management. Lancet Respir Med. 2021; 9(11):1313-1327. DOI: 10.1016/S2213-2600(21)00228-9. View

4.
Taveira-DaSilva A, Moss J . EPIDEMIOLOGY, PATHOGENESIS and DIAGNOSIS of LYMPHANGIOLEIOMYOMATOSIS. Expert Opin Orphan Drugs. 2016; 4(4):369-378. PMC: 5098502. DOI: 10.1517/21678707.2016.1148597. View

5.
Taveira-DaSilva A, Pacheco-Rodriguez G, Moss J . The natural history of lymphangioleiomyomatosis: markers of severity, rate of progression and prognosis. Lymphat Res Biol. 2010; 8(1):9-19. PMC: 2883494. DOI: 10.1089/lrb.2009.0024. View