» Articles » PMID: 38384359

Comparative Analysis of Three Nickel-Titanium Rotary Files in Severely Curved L-Shaped Root Canals: Preparation Time, Aberrations, and Fracture Rates

Abstract

Background: This simulated study of 30 severely curved L-shaped root canals aimed to compare preparation time, aberrations, width measurements, and fractured files of three nickel-titanium (Ni-Ti) files, namely, ProTaper, ProTaper Next (PTN), and WaveOne (WO).

Methods: Thirty simulated L-curved root canals of resin blocks were randomly divided into three groups. The canals were prepared to a tip size of 25 using ProTaper, PTN, and WO rotary file systems. Pre- and post-operative views for each sample were captured by a professional camera at a standardized distance and position. Blue India ink was injected into the pre-operative canals, and red India ink was injected into the post-operative canals to give a clear superimposition image. Five points were assessed through the halfway of the canal to the orifice (area between the beginning of curvature and apical end point). Preparation time, aberrations, width measurements, and fractured files were recorded and analyzed.

Results: Mean preparation time was longest in ProTaper (4.89±0.68 minutes). PTN and WO were the fastest in preparing the canals (about 3 minutes). A statistically significant difference was found between WO and ProTaper & PTN and ProTaper (p=0.000), while the difference was non-significant (p > 0.05) between WO and PTN. Nine aberrations consisting of three zips, one ledge and one outer widening were related to ProTaper, while WO recorded a ledge and fractured file, but for PTN system, it verified an outer widening and ledge. Only one WO file fractured, with no deformation observed in the other instruments. No significance was recorded among the width measurements in the different levels.

Conclusion: ProTaper next achieved faster cutting than the ProTaper and WO file systems. PTN maintained the best apical termination position and produced the least canal aberration, followed by WO and ProTaper.

Citing Articles

Evaluation of shaping ability, apical transportation and centering ratio of T-Endo Must, WaveOne Gold, and Trunatomy in resin blocks.

Karaca Sakalli A, Ekici M PeerJ. 2024; 12:e18088.

PMID: 39421425 PMC: 11485059. DOI: 10.7717/peerj.18088.

References
1.
Elnaghy A, Elsaka S . Assessment of the mechanical properties of ProTaper Next Nickel-titanium rotary files. J Endod. 2014; 40(11):1830-4. DOI: 10.1016/j.joen.2014.06.011. View

2.
Weine F, Kelly R, Lio P . The effect of preparation procedures on original canal shape and on apical foramen shape. J Endod. 1975; 1(8):255-62. DOI: 10.1016/S0099-2399(75)80037-9. View

3.
Schilder H . Cleaning and shaping the root canal. Dent Clin North Am. 1974; 18(2):269-96. View

4.
Tabassum S, Zafar K, Umer F . Nickel-Titanium Rotary File Systems: What's New?. Eur Endod J. 2020; 4(3):111-117. PMC: 7006588. DOI: 10.14744/eej.2019.80664. View

5.