» Articles » PMID: 38375348

Iliac Artery-enteric Fistulas Following Failed Pancreatic Transplant

Overview
Date 2024 Feb 20
PMID 38375348
Authors
Affiliations
Soon will be listed here.
Abstract

Arterial-enteric fistulas occur from a multitude of causes, especially following surgical manipulation of vasculature. The development of an iliac artery-enteric fistula (IEF) occurs rarely in patients with failed pancreatic transplants. IEFs warrant urgent intervention due to the high mortality from hemorrhagic and septic shock. The diagnosis can be delayed by a lack of suspicion, the low sensitivity of diagnostic tests, and the nonspecific signs of fistulas on computed tomography. The management of IEFs is adapted from guidelines for arterial-enteric fistulas of other causes, with little consensus on ideal vascular reconstruction and postoperative antimicrobial management. The outcomes are limited to the short-term results from case reports and case series. We report two cases of IEFs in patients with a history of simultaneous pancreatic kidney transplant. Our patients underwent successful resolution of gastrointestinal bleeding and sepsis, with definitive management of fistula resection and interposition iliac artery bypass. The index of suspicion for IEFs should be high, and they should be considered as a source of anemia or gastrointestinal bleeding of an unknown source in patients with failed pancreatic transplant. Definitive management should be pursued in patients who can tolerate fistula resection, allograft explant, and arterial reconstruction.

References
1.
Kakkos S, Antoniadis P, Klonaris C, Papazoglou K, Giannoukas A, Matsagkas M . Open or endovascular repair of aortoenteric fistulas? A multicentre comparative study. Eur J Vasc Endovasc Surg. 2011; 41(5):625-34. DOI: 10.1016/j.ejvs.2010.12.026. View

2.
Oderich G, Bower T, Hofer J, Kalra M, Duncan A, Wilson J . In situ rifampin-soaked grafts with omental coverage and antibiotic suppression are durable with low reinfection rates in patients with aortic graft enteric erosion or fistula. J Vasc Surg. 2010; 53(1):99-106, 107.e1-7. DOI: 10.1016/j.jvs.2010.08.018. View

3.
Villa M, Siskind E, Jaimes N, Eckstein D, Bhaskaran M, Sachdeva M . Arterio-enteric fistula in failed enteric-drained pancreas transplants: an impending danger. Int J Angiol. 2014; 23(1):65-8. PMC: 3933477. DOI: 10.1055/s-0033-1349169. View

4.
Lazaris A, Tsapralis D, Patapis P, Mproutzos E, Tzathas H, Kakisis J . Aortoiliac endograft-enteric fistula due to an ingested toothpick. J Vasc Surg. 2009; 50(3):640-3. DOI: 10.1016/j.jvs.2009.03.059. View

5.
Heinola I, Kantonen I, Jaroma M, Alback A, Vikatmaa P, Aho P . Editor's Choice - Treatment of Aortic Prosthesis Infections by Graft Removal and In Situ Replacement with Autologous Femoral Veins and Fascial Strengthening. Eur J Vasc Endovasc Surg. 2015; 51(2):232-9. DOI: 10.1016/j.ejvs.2015.09.015. View