» Articles » PMID: 38372479

In Vivo Cardiac Electrophysiology in Mice: Determination of Atrial and Ventricular Arrhythmic Substrates

Overview
Journal Curr Protoc
Specialties Biology
Science
Date 2024 Feb 19
PMID 38372479
Authors
Affiliations
Soon will be listed here.
Abstract

Cardiac arrhythmias are a common cardiac condition that might lead to fatal outcomes. A better understanding of the molecular and cellular basis of arrhythmia mechanisms is necessary for the development of better treatment modalities. To aid these efforts, various mouse models have been developed for studying cardiac arrhythmias. Both genetic and surgical mouse models are commonly used to assess the incidence and mechanisms of arrhythmias. Since spontaneous arrhythmias are uncommon in healthy young mice, intracardiac programmed electrical stimulation (PES) can be performed to assess the susceptibility to pacing-induced arrhythmias and uncover the possible presence of a proarrhythmogenic substrate. This procedure is performed by positioning an octopolar catheter inside the right atrium and ventricle of the heart through the right jugular vein. PES can provide insights into atrial and ventricular electrical activity and reveal whether atrial and/or ventricular arrhythmias are present or can be induced. Here, we explain detailed procedures used to perform this technique, possible troubleshooting scenarios, and methods to interpret the results obtained. © 2024 Wiley Periodicals LLC. Basic Protocol: Programmed electrical stimulation in mice.

References
1.
Markel M, Miles W, Luck J, Klein L, Prystowsky E . Differential effects of isoproterenol on sustained ventricular tachycardia before and during procainamide and quinidine antiarrhythmic drug therapy. Circulation. 1993; 87(3):783-92. DOI: 10.1161/01.cir.87.3.783. View

2.
Verheule S, Sato T, Everett 4th T, Engle S, Otten D, Rubart-von der Lohe M . Increased vulnerability to atrial fibrillation in transgenic mice with selective atrial fibrosis caused by overexpression of TGF-beta1. Circ Res. 2004; 94(11):1458-65. PMC: 2129102. DOI: 10.1161/01.RES.0000129579.59664.9d. View

3.
Fu F, Pietropaolo M, Cui L, Pandit S, Li W, Tarnavski O . Lack of authentic atrial fibrillation in commonly used murine atrial fibrillation models. PLoS One. 2022; 17(1):e0256512. PMC: 8741011. DOI: 10.1371/journal.pone.0256512. View

4.
Pan X, Philippen L, Lahiri S, Lee C, Park S, Word T . In Vivo Ryr2 Editing Corrects Catecholaminergic Polymorphic Ventricular Tachycardia. Circ Res. 2018; 123(8):953-963. PMC: 6206886. DOI: 10.1161/CIRCRESAHA.118.313369. View

5.
Dobrev D, Wehrens X . Mouse Models of Cardiac Arrhythmias. Circ Res. 2018; 123(3):332-334. PMC: 6055525. DOI: 10.1161/CIRCRESAHA.118.313406. View