» Articles » PMID: 38341576

Precise Control of Digital Dental Unit to Reduce Aerosol and Splatter Production: New Challenges for Future Epidemics

Overview
Journal BMC Oral Health
Publisher Biomed Central
Specialty Dentistry
Date 2024 Feb 10
PMID 38341576
Authors
Affiliations
Soon will be listed here.
Abstract

Background: During dental procedures, critical parameters, such as cooling condition, speed of the rotary dental turbine (handpiece), and distance and angle from pollution sources, were evaluated for transmission risk of the Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2), simulated by spiking in a plasmid encoding a modified viral spike protein, HexaPro (S6P), in droplets and aerosols.

Methods: To simulate routine operation in dental clinics, dental procedures were conducted on a dental manikin within a digital dental unit, incorporating different dental handpiece speeds and cooling conditions. The tooth model was immersed in Coomassie brilliant blue dye and was pre-coated with 100 μL water spiked-in with S6P-encoding plasmid. Furthermore, the manikin was surrounded by filter papers and Petri dishes positioned at different distances and angles. Subsequently, the filter papers and Petri dishes were collected to evaluate the aerosol splash points and the viral load of S6P-encoding plasmid in aerosols and splatters generated during the dental procedure.

Results: Aerosol splashing generated a localized pollution area extended up to 60 cm, with heightened contamination risks concentrated within a 30 cm radius. Significant differences in aerosol splash points and viral load by different turbine handpiece speeds under any cooling condition (P < 0.05) were detected. The highest level of aerosol splash points and viral load were observed when the handpiece speed was set at 40,000 rpm. Conversely, the lowest level of aerosol splash point and viral load were found at a handpiece speed of 10,000 rpm. Moreover, the aerosol splash points with higher viral load were more prominent in the positions of the operator and assistant compared to other positions. Additionally, the position of the operator exhibited the highest viral load among all positions.

Conclusions: To minimize the spread of aerosol and virus in clinics, dentists are supposed to adopt the minimal viable speed of a dental handpiece with limited cooling water during dental procedures. In addition, comprehensive personal protective equipment is necessary for both dental providers and dental assistants.

References
1.
Johnson A, Huang B, Galina I, Ngo A, Uppgaard R . Splatter generated by oral surgery irrigation and its implication for infection control. Clin Oral Investig. 2023; 27(11):6607-6612. DOI: 10.1007/s00784-023-05266-x. View

2.
Dudding T, Sheikh S, Gregson F, Haworth J, Haworth S, Main B . A clinical observational analysis of aerosol emissions from dental procedures. PLoS One. 2022; 17(3):e0265076. PMC: 8912243. DOI: 10.1371/journal.pone.0265076. View

3.
Ionescu A, Cagetti M, Ferracane J, Garcia-Godoy F, Brambilla E . Topographic aspects of airborne contamination caused by the use of dental handpieces in the operative environment. J Am Dent Assoc. 2020; 151(9):660-667. PMC: 7328555. DOI: 10.1016/j.adaj.2020.06.002. View

4.
Takanabe Y, Maruoka Y, Kondo J, Yagi S, Chikazu D, Okamoto R . Dispersion of Aerosols Generated during Dental Therapy. Int J Environ Res Public Health. 2021; 18(21). PMC: 8583477. DOI: 10.3390/ijerph182111279. View

5.
Srinivasan M, Thyvalikakath T, Cook B, Zero D . COVID-19 and Saliva: A Primer for Dental Health Care Professionals. Int Dent J. 2021; 71(1):5-8. PMC: 7461162. DOI: 10.1111/idj.12606. View