Aims: When it occurs, pulmonary vein (PV) stenosis after atrial fibrillation (AF) ablation is associated with significant morbidity. Even mild-to-moderate PV narrowing may have long-term implications. Unlike thermal ablation energies, such as radiofrequency (RF) or cryothermy, pulsed field ablation (PFA) is a non-thermal modality associated with less fibrotic proliferation. Herein, we compared the effects of PFA vs. thermal ablation on PV narrowing after AF ablation.
Methods And Results: ADVENT was a multi-centre, randomized, single-blind study comparing PFA (pentaspline catheter) with thermal ablation-force-sensing RF or cryoballoon (CB)-to treat drug-refractory paroxysmal AF. Pulmonary vein diameter and aggregate cross-sectional area were obtained by baseline and 3-month imaging. The pre-specified, formally tested, secondary safety endpoint compared a measure of PV narrowing between PFA vs. thermal groups, with superiority defined by posterior probability > 0.975. Among subjects randomized to PFA (n = 305) or thermal ablation (n = 302), 259 PFA and 255 thermal ablation (137 RF and 118 CB) subjects had complete baseline and 3-month PV imaging. No subject had significant (≥70%) PV stenosis. Change in aggregate PV cross-sectional area was less with PFA (-0.9%) than thermal ablation (-12%, posterior probability > 0.999)-primarily driven by the RF sub-cohort (-19.5%) vs. CB sub-cohort (-3.3%). Almost half of all PFA PV diameters did not decrease, but the majority (80%) of RF PVs decreased, regardless of PV anatomic location.
Conclusion: In this first randomized comparison of PFA vs. thermal ablation, PFA resulted in less PV narrowing-thereby underscoring the qualitatively differential and favourable impact of PFA on PV tissue.
Catheter Ablation in Atrial Fibrillation: Recent Advances.
Singh S, Garg L, Kanjwal M, Bliden K, Tantry U, Gurbel P J Clin Med. 2025; 13(24.
PMID: 39768622 PMC: 11679530. DOI: 10.3390/jcm13247700.
Ventilation/Perfusion Mismatch in Pulmonary Vein Stenosis Secondary to Atrial Fibrillation Ablation.
Bollos L, Kasai R, Otsuka H, Otomi Y, Matsuura T, Otani T Asia Ocean J Nucl Med Biol. 2025; 13(1):62-69.
PMID: 39744058 PMC: 11682475. DOI: 10.22038/aojnmb.2024.79650.1561.
Cristiano E, Ali H, Celentano E, Cappato R World J Cardiol. 2024; 16(12):677-682.
PMID: 39734816 PMC: 11669968. DOI: 10.4330/wjc.v16.i12.677.
Considerations regarding safety with pulsed field ablation for atrial fibrillation.
Sugrue A, Shabtaie S, Tan N, Maor E, Kapa S, Asirvatham S Heart Rhythm O2. 2024; 5(9):655-661.
PMID: 39493907 PMC: 11524966. DOI: 10.1016/j.hroo.2024.08.002.
Pulsed Field Ablation of Atrial Fibrillation: A Novel Technology for Safer and Faster Ablation.
Carta-Bergaz A, Rios-Munoz G, Avila P, Atienza F, Gonzalez-Torrecilla E, Arenal A Biomedicines. 2024; 12(10).
PMID: 39457545 PMC: 11504058. DOI: 10.3390/biomedicines12102232.