» Articles » PMID: 38296881

The Dubousset Functional Test: a Reliable and Valid Test in Early Stage Parkinson's Disease Patients

Overview
Journal Neurol Sci
Specialty Neurology
Date 2024 Jan 31
PMID 38296881
Authors
Affiliations
Soon will be listed here.
Abstract

Introduction: Dubousset Functional Test (DFT) is an assessment test evaluating the functional capacity and dynamic balance. The study aimed to examine the reliability, validity, and responsiveness of the DFT in early stage Parkinson's disease (PD) patients.

Methods: This was a cross-sectional study. Thirty-three early stage PD patients were recruited. The DFT was performed along with the Timed Up and Go (TUG) test, dual-task TUG, Functional Reach Test (FRT), 3-m backward walk test (3MBWT), Tinetti Performance-Oriented Mobility Assessment (POMA), and Berg Balance Scale (BBS).

Results: The test-retest reliability of the subcomponents of the DFT was excellent. The ICCs were as follows: 0.952, 0.955, 0.917, and 0.919, respectively. The correlation with subcomponents of DFT and TUG, dual-task TUG, FRT, 3MBWT, BBS, and POMA was found to be statistically significant (p < 0.05). The standard measurement errors of the subcomponents of the DFT were 1.45, 1.39, 1.70, and 1.57, respectively. The minimal clinically important difference (MCID) of the subcomponents was 2.05, 1.97, 2.41, and 2.22, respectively.

Conclusion: The DFT is a reliable, valid, and easy-to-administer tool in assessing the balance and physical function of early stage PD patients.

References
1.
Granacher U, Gollhofer A, Hortobagyi T, Kressig R, Muehlbauer T . The importance of trunk muscle strength for balance, functional performance, and fall prevention in seniors: a systematic review. Sports Med. 2013; 43(7):627-41. DOI: 10.1007/s40279-013-0041-1. View

2.
. The Unified Parkinson's Disease Rating Scale (UPDRS): status and recommendations. Mov Disord. 2003; 18(7):738-50. DOI: 10.1002/mds.10473. View

3.
Petersen C, Steffen T, Paly E, Dvorak L, Nelson R . Reliability and Minimal Detectable Change for Sit-to-Stand Tests and the Functional Gait Assessment for Individuals With Parkinson Disease. J Geriatr Phys Ther. 2016; 40(4):223-226. DOI: 10.1519/JPT.0000000000000102. View

4.
Carter V, Jain T, James J, Cornwall M, Aldrich A, de Heer H . The 3-m Backwards Walk and Retrospective Falls: Diagnostic Accuracy of a Novel Clinical Measure. J Geriatr Phys Ther. 2017; 42(4):249-255. DOI: 10.1519/JPT.0000000000000149. View

5.
Hughes A, Daniel S, Kilford L, Lees A . Accuracy of clinical diagnosis of idiopathic Parkinson's disease: a clinico-pathological study of 100 cases. J Neurol Neurosurg Psychiatry. 1992; 55(3):181-4. PMC: 1014720. DOI: 10.1136/jnnp.55.3.181. View