» Articles » PMID: 38291034

An Extensive Quantitative Analysis of the Effects of Errors in Beat-to-beat Intervals on All Commonly Used HRV Parameters

Overview
Journal Sci Rep
Specialty Science
Date 2024 Jan 30
PMID 38291034
Authors
Affiliations
Soon will be listed here.
Abstract

Heart rate variability (HRV) analysis is often used to estimate human health and fitness status. More specifically, a range of parameters that express the variability in beat-to-beat intervals are calculated from electrocardiogram beat detections. Since beat detection may yield erroneous interval data, these errors travel through the processing chain and may result in misleading parameter values that can lead to incorrect conclusions. In this study, we utilized Monte Carlo simulation on real data, Kolmogorov-Smirnov tests and Bland-Altman analysis to carry out extensive analysis of the noise sensitivity of different HRV parameters. The used noise models consider Gaussian and student-t distributed noise. As a result we observed that commonly used HRV parameters (e.g. pNN50 and LF/HF ratio) are especially sensitive to noise and that all parameters show biases to some extent. We conclude that researchers should be careful when reporting different HRV parameters, consider the distributions in addition to mean values, and consider reference data if applicable. The analysis of HRV parameter sensitivity to noise and resulting biases presented in this work generalizes over a wide population and can serve as a reference and thus provide a basis for the decision about which HRV parameters to choose under similar conditions.

References
1.
Kim K, Lim Y, Kim J, Park K . Effect of missing RR-interval data on heart rate variability analysis in the time domain. Physiol Meas. 2007; 28(12):1485-94. DOI: 10.1088/0967-3334/28/12/003. View

2.
Guo Y, Palmer J, Strasser F, Yusuf S, Bruera E . Heart rate variability as a measure of autonomic dysfunction in men with advanced cancer. Eur J Cancer Care (Engl). 2013; 22(5):612-6. PMC: 3745803. DOI: 10.1111/ecc.12066. View

3.
Hoog Antink C, Leonhardt S, Walter M . Local Interval Estimation Improves Accuracy and Robustness of Heart Rate Variability Derivation from Photoplethysmography. Annu Int Conf IEEE Eng Med Biol Soc. 2018; 2018:3558-3561. DOI: 10.1109/EMBC.2018.8512908. View

4.
Goldberger A, Amaral L, Glass L, Hausdorff J, Ivanov P, Mark R . PhysioBank, PhysioToolkit, and PhysioNet: components of a new research resource for complex physiologic signals. Circulation. 2000; 101(23):E215-20. DOI: 10.1161/01.cir.101.23.e215. View

5.
Brennan M, Palaniswami M, Kamen P . Do existing measures of Poincaré plot geometry reflect nonlinear features of heart rate variability?. IEEE Trans Biomed Eng. 2001; 48(11):1342-7. DOI: 10.1109/10.959330. View