» Articles » PMID: 38194410

MOCCal: A Multiomic CCS Calibrator for Traveling Wave Ion Mobility Mass Spectrometry

Overview
Journal Anal Chem
Specialty Chemistry
Date 2024 Jan 9
PMID 38194410
Authors
Affiliations
Soon will be listed here.
Abstract

Ion mobility mass spectrometry (IM-MS) is a rapid, gas-phase separation technology that can resolve ions on the basis of their and ratios. Since each class of biomolecule has a unique relationship between size and mass, IM-MS spectra of complex biological samples are organized into trendlines that each contain one type of biomolecule (i.e., lipid, peptide, metabolite). These trendlines can aid in the identification of unknown ions by providing a general classification, while more specific identifications require the conversion of IM arrival times to collision cross section (CCS) values to minimize instrument-to-instrument variability. However, the process of converting IM arrival times to CCS values varies between the different IM devices. Arrival times from traveling wave ion mobility (TWIM) devices must undergo a calibration process to obtain CCS values, which can impart biases if the calibrants are not structurally similar to the analytes. For multiomic mixtures, several different types of calibrants must be used to obtain the most accurate CCS values from TWIM platforms. Here we describe the development of a multiomic CCS calibration tool, MOCCal, to automate the assignment of unknown features to the power law calibration that provides the most accurate CCS value. MOCCal calibrates every experimental arrival time with up to three class-specific calibration curves and uses the difference (in Å) between the calibrated CCS value and CCS vs / regression lines to determine the best calibration curve. Using real and simulated multiomic samples, we demonstrate that MOCCal provides accurately calibrated CCS values for small molecules, lipids, and peptides.

Citing Articles

MobiLipid: A Tool for Enhancing CCS Quality Control of Ion Mobility-Mass Spectrometry Lipidomics by Internal Standardization.

Hildebrand F, Koellensperger G, Causon T Anal Chem. 2024; 96(19):7380-7385.

PMID: 38693701 PMC: 11099887. DOI: 10.1021/acs.analchem.4c01253.


Computational tools and algorithms for ion mobility spectrometry-mass spectrometry.

Ross D, Bhotika H, Zheng X, Smith R, Burnum-Johnson K, Bilbao A Proteomics. 2024; 24(12-13):e2200436.

PMID: 38438732 PMC: 11632599. DOI: 10.1002/pmic.202200436.

References
1.
Bowden J, Heckert A, Ulmer C, Jones C, Koelmel J, Abdullah L . Harmonizing lipidomics: NIST interlaboratory comparison exercise for lipidomics using SRM 1950-Metabolites in Frozen Human Plasma. J Lipid Res. 2017; 58(12):2275-2288. PMC: 5711491. DOI: 10.1194/jlr.M079012. View

2.
Rainey M, Watson C, Asef C, Foster M, Baker E, Fernandez F . CCS Predictor 2.0: An Open-Source Jupyter Notebook Tool for Filtering Out False Positives in Metabolomics. Anal Chem. 2022; 94(50):17456-17466. PMC: 9772062. DOI: 10.1021/acs.analchem.2c03491. View

3.
Luo F, Yu Z, Zhou Q, Huang A . Multi-Omics-Based Discovery of Plant Signaling Molecules. Metabolites. 2022; 12(1). PMC: 8777911. DOI: 10.3390/metabo12010076. View

4.
May J, Goodwin C, Lareau N, Leaptrot K, Morris C, Kurulugama R . Conformational ordering of biomolecules in the gas phase: nitrogen collision cross sections measured on a prototype high resolution drift tube ion mobility-mass spectrometer. Anal Chem. 2014; 86(4):2107-16. PMC: 3931330. DOI: 10.1021/ac4038448. View

5.
Meier F, Kohler N, Brunner A, Wanka J, Voytik E, Strauss M . Deep learning the collisional cross sections of the peptide universe from a million experimental values. Nat Commun. 2021; 12(1):1185. PMC: 7896072. DOI: 10.1038/s41467-021-21352-8. View