» Articles » PMID: 38178053

The Effect of Pterygium on Front and Back Corneal Astigmatism and Aberrations in Natural-light and Low-light Conditions

Overview
Journal BMC Ophthalmol
Publisher Biomed Central
Specialty Ophthalmology
Date 2024 Jan 4
PMID 38178053
Authors
Affiliations
Soon will be listed here.
Abstract

Background: To investigate the effect of different sizes of pterygium on the front and back corneal topography, refractive changes and aberrations in natural-light and low-light conditions.

Methods: Sixty subjects with unilateral primary nasal pterygium were enrolled in this study. All the patients' uncorrected, best spectacle-corrected visual acuity, corneal topographic aberration data in 3 mm and 7 mm areas were collected. The pterygium size was evaluated by the slit-lamp photography and Sirius Scheimpflug Analyzer.

Results: The front topographic astigmatism values, corneal total aberrations, and higher-order aberrations in 3 mm and 7 mm areas were higher in the pterygium group than those in the control group. The pterygium horizontal length and thickness were moderately to strongly correlated with astigmatism and RMS of aberrations, while pterygium vertical length showed no or just mild correlation with the corneal astigmatism and aberrations. Compared to the readings in 3 mm area, the front and back corneal astigmatism and aberrations were larger in 7 mm area.

Conclusions: Pterygium led to visual impairment by inducing astigmatism and aberrations. In low-light condition, the visual function worsened due to increased corneal astigmatism values and aberrations.

References
1.
Fernandes A, Salomao S, Ferraz N, Mitsuhiro M, Furtado J, Munoz S . Pterygium in adults from the Brazilian Amazon Region: prevalence, visual status and refractive errors. Br J Ophthalmol. 2019; 104(6):757-763. DOI: 10.1136/bjophthalmol-2019-314131. View

2.
Gharieb H, Ashour D, Saleh M, Othman I . Measurement of central corneal thickness using Orbscan 3, Pentacam HR and ultrasound pachymetry in normal eyes. Int Ophthalmol. 2020; 40(7):1759-1764. DOI: 10.1007/s10792-020-01344-1. View

3.
Savini G, Schiano-Lomoriello D, Hoffer K . Repeatability of automatic measurements by a new anterior segment optical coherence tomographer combined with Placido topography and agreement with 2 Scheimpflug cameras. J Cataract Refract Surg. 2018; 44(4):471-478. DOI: 10.1016/j.jcrs.2018.02.015. View

4.
Gao H, Du Z, Yan P, Zhang Y, Li T . [Comparison of contrast sensitivity and wavefront aberrations with myopic]. Zhonghua Yan Ke Za Zhi. 2018; 54(10):748-755. DOI: 10.3760/cma.j.issn.0412-4081.2018.10.006. View

5.
Kampitak K, Leelawongtawun W, Leeamornsiri S, Suphachearaphan W, Thitiwichienlert S . A Comparative Study of Higher order Aberrations between Pterygium and Non-Pterygium Eyes. J Med Assoc Thai. 2018; 99 Suppl 4:S178-81. View