» Articles » PMID: 38137816

Current Usefulness of Transesophageal Echocardiography in Patients Undergoing Transcatheter Aortic Valve Replacement

Abstract

This review article describes in depth the current usefulness of transesophageal echocardiography in patients who undergo transcatheter aortic valve replacement. Pre-intervention, 3D-transesophageal echocardiography allows us to accurately evaluate the aortic valve morphology and to measure the valve annulus, helping us to choose the appropriate size of the prosthesis, especially useful in cases where the computed tomography is not of adequate quality. Although it is not currently used routinely during the intervention, it remains essential in those cases of greater complexity, such as for patients with greater calcification and bicuspid valve, mechanical mitral prosthesis, and "valve in valve" procedures. Three-dimensional transesophageal echocardiography is the best technique to detect and quantify paravalvular regurgitation, a fundamental aspect to decide whether immediate valve postdilation is needed. It also allows to detect early any immediate complications such as cardiac tamponade, aortic hematoma or dissection, migration of the prosthesis, malfunction of the prosthetic leaflets, or the appearance of segmental contractility disorders due to compromise of the coronary arteries ostium. Transesophageal echocardiography is also very useful in follow-up, to check the proper functioning of the prosthesis and to rule out complications such as thrombosis of the leaflets, endocarditis, or prosthetic degeneration.

Citing Articles

A stuck leaflet after balloon post-dilatation in transcatheter aortic valve implantation with a SAPIEN-3 ultra RESILIA valve: a case report.

Yamazoe S, Ogawa Y, Kano N, Mamiya K, Kawaguchi K Eur Heart J Case Rep. 2025; 9(1):ytae697.

PMID: 39802063 PMC: 11718390. DOI: 10.1093/ehjcr/ytae697.


The Other Side of the Coin: Transesophageal Echocardiography Complications following Cardiac Surgery and Transcatheter Structural Heart Interventions.

de Luca V, Cammalleri V, Antonelli G, Bombace S, Ruf T, Gossler T J Clin Med. 2024; 13(15).

PMID: 39124557 PMC: 11312835. DOI: 10.3390/jcm13154291.

References
1.
Franco A, Gerli C, Ruggeri L, Monaco F . Anaesthetic management of transcatheter aortic valve implantation. Ann Card Anaesth. 2012; 15(1):54-63. DOI: 10.4103/0971-9784.91484. View

2.
Smith L, Dworakowski R, Bhan A, Delithanasis I, Hancock J, MacCarthy P . Real-time three-dimensional transesophageal echocardiography adds value to transcatheter aortic valve implantation. J Am Soc Echocardiogr. 2013; 26(4):359-69. DOI: 10.1016/j.echo.2013.01.014. View

3.
Kasel A, Cassese S, Bleiziffer S, Amaki M, Hahn R, Kastrati A . Standardized imaging for aortic annular sizing: implications for transcatheter valve selection. JACC Cardiovasc Imaging. 2013; 6(2):249-62. DOI: 10.1016/j.jcmg.2012.12.005. View

4.
Lehmkuhl L, Foldyna B, Von Aspern K, Lucke C, Grothoff M, Nitzsche S . Inter-individual variance and cardiac cycle dependency of aortic root dimensions and shape as assessed by ECG-gated multi-slice computed tomography in patients with severe aortic stenosis prior to transcatheter aortic valve implantation: is it.... Int J Cardiovasc Imaging. 2012; 29(3):693-703. PMC: 3608865. DOI: 10.1007/s10554-012-0123-4. View

5.
Jilaihawi H, Doctor N, Kashif M, Chakravarty T, Rafique A, Makar M . Aortic annular sizing for transcatheter aortic valve replacement using cross-sectional 3-dimensional transesophageal echocardiography. J Am Coll Cardiol. 2013; 61(9):908-16. DOI: 10.1016/j.jacc.2012.11.055. View