Quantifying Iodine Concentration in the Normal Bowel Wall Using Dual-energy CT: Influence of Patient and Contrast Characteristics

Overview
Journal Sci Rep
Specialty Science
Date 2023 Dec 20
PMID 38123632
Authors
Affiliations
Soon will be listed here.
Abstract

This study aimed to establish quantitative references of the normal bowel wall iodine concentration (BWIC) using dual energy CT (DECT). This single-center retrospective study included 248 patients with no history of gastrointestinal disease who underwent abdominal contrast-enhanced DECT between January and April 2022. The BWIC was normalized by the iodine concentration of upper abdominal organs (BWIC) and the iodine concentration (IC) of the aorta (BWIC). BWIC decreased from the stomach to the rectum (mean 2.16 ± 0.63 vs. 2.19 ± 0.63 vs. 2.1 ± 0.58 vs. 1.67 ± 0.47 vs. 1.31 ± 0.4 vs. 1.18 ± 0.34 vs. 0.94 ± 0.26 mgI/mL for the stomach, duodenum, jejunum, ileum, right colon, left colon and rectum, respectively; P < 0.001). By multivariate analysis, BWIC was associated with a higher BMI (OR:1.01, 95% CI 1.00-1.02, P < 0.001) and with a higher injected contrast dose (OR: 1.51; 95% CI 1.36-1.66, P < 0.001 and 2.06; 95% CI 1.88-2.26, P < 0.001 for 500 mgI/kg and 600 mgI/kg doses taking 400 mgI/kg dose as reference). The BWIC was shown independent from patients and contrast-related variables while the BWIC was not. BWIC varies according to bowel segments and is dependent on the total iodine dose injected. It shall be normalized with the IC of the upper abdominal organs.

References
1.
Zamora C, Castillo M . Historical Perspective of Imaging Contrast Agents. Magn Reson Imaging Clin N Am. 2017; 25(4):685-696. DOI: 10.1016/j.mric.2017.06.002. View

2.
Bae K . Intravenous contrast medium administration and scan timing at CT: considerations and approaches. Radiology. 2010; 256(1):32-61. DOI: 10.1148/radiol.10090908. View

3.
Kondo H, Kanematsu M, Goshima S, Tomita Y, Kim M, Moriyama N . Body size indexes for optimizing iodine dose for aortic and hepatic enhancement at multidetector CT: comparison of total body weight, lean body weight, and blood volume. Radiology. 2009; 254(1):163-9. DOI: 10.1148/radiol.09090369. View

4.
Goshima S, Kanematsu M, Kondo H, Yokoyama R, Miyoshi T, Kato H . Pancreas: optimal scan delay for contrast-enhanced multi-detector row CT. Radiology. 2006; 241(1):167-74. DOI: 10.1148/radiol.2411051338. View

5.
de Jong D, van Cooten V, Veldhuis W, de Jong P, Kok M . Individualized Contrast Media Application Based on Body Weight and Contrast Enhancement in Computed Tomography of Livers without Steatosis. Diagnostics (Basel). 2022; 12(7). PMC: 9322492. DOI: 10.3390/diagnostics12071551. View