» Articles » PMID: 38097283

Quality of Fluid Balance Charting and Interventions to Improve It: a Systematic Review

Overview
Journal BMJ Open Qual
Specialty Health Services
Date 2023 Dec 14
PMID 38097283
Authors
Affiliations
Soon will be listed here.
Abstract

Introduction: Fluid balance monitoring is pivotal to patients' health. Thus, fluid balance charting is an essential part of clinical nursing documentation. This systematic review aimed to investigate and describe the quality of fluid balance monitoring in medical, surgical and intensive care units, with an emphasis on the completeness of charting data, calculation errors and accuracy, and to evaluate methods used to improve fluid balance charting.

Materials And Methods: Quantitative studies involving adult patients and reporting data on fluid balance monitoring were included in the review. We searched MEDLINE, Embase, CINAHL and the Cochrane Library. The risk of bias in the included studies was assessed using tools developed by the Joanna Briggs Institute.

Results: We included a total of 23 studies, which involved 6649 participants. The studies were quasi-experimental, cohort or prevalence studies, and every third study was of low quality. Definitions of 'completeness' varied, as well as patient categories and time of evaluation. Eighteen studies reported the prevalence of patients with complete fluid balance charts; of those, 10 reported that not more than 50% of fluid balance charts were complete. Studies addressing calculation errors found them in 25%-35% of charts, including omissions of, for example, intravenous medications. The reported interventions consisted of various components such as policies, education, equipment, visual aids, surveillance and dissemination of results. Among studies evaluating interventions, only 38% (5 of 13) achieved compliance with at least 75% of complete fluid balance charts. Due to the heterogeneity of the studies, a meta-analysis was not possible.

Conclusion: The quality of fluid balance charting is inadequate in most studies, and calculation errors influence quality. Interventions included several components, and the impact on the completion of fluid balance charts varied.

Citing Articles

Evaluation of a real-life experience with a digital fluid balance monitoring technology.

Leinum L, Baandrup A, Gogenur I, Krogsgaard M, Azawi N Technol Health Care. 2024; 32(6):3913-3924.

PMID: 39093083 PMC: 11612992. DOI: 10.3233/THC-231303.


Digitizing fluid balance monitoring may offer a solution for optimizing patient care.

Leinum L, Baandrup A, Gogenur I, Krogsgaard M, Azawi N Technol Health Care. 2023; 32(2):1111-1122.

PMID: 37781831 PMC: 10977352. DOI: 10.3233/THC-230664.

References
1.
El-Sharkawy A, Sahota O, Lobo D . Acute and chronic effects of hydration status on health. Nutr Rev. 2015; 73 Suppl 2:97-109. DOI: 10.1093/nutrit/nuv038. View

2.
McGloin S . The ins and outs of fluid balance in the acutely ill patient. Br J Nurs. 2014; 24(1):14-8. DOI: 10.12968/bjon.2015.24.1.14. View

3.
Fennelly O, Grogan L, Reed A, Hardiker N . Use of standardized terminologies in clinical practice: A scoping review. Int J Med Inform. 2021; 149:104431. DOI: 10.1016/j.ijmedinf.2021.104431. View

4.
Tura A, Aboul-Ela Y, Fage S, Ahmed S, Scherjon S, van Roosmalen J . Introduction of Criterion-Based Audit of Postpartum Hemorrhage in a University Hospital in Eastern Ethiopia: Implementation and Considerations. Int J Environ Res Public Health. 2020; 17(24). PMC: 7764538. DOI: 10.3390/ijerph17249281. View

5.
Brandstrup B, Tonnesen H, Beier-Holgersen R, Hjortso E, Ording H, Lindorff-Larsen K . Effects of intravenous fluid restriction on postoperative complications: comparison of two perioperative fluid regimens: a randomized assessor-blinded multicenter trial. Ann Surg. 2003; 238(5):641-8. PMC: 1356139. DOI: 10.1097/01.sla.0000094387.50865.23. View