Abstract

Antimicrobial resistance (AMR) is a global health threat, progressively emerging as a significant public health issue. Therefore, an antibiotic susceptibility study is a powerful method for combating antimicrobial resistance. Antibiotic susceptibility study collectively helps in evaluating both genotypic and phenotypic resistance. However, current traditional antibiotic susceptibility study methods are time-consuming, laborious, and expensive. Hence, there is a pressing need to develop simple, rapid, miniature, and affordable devices to prevent antimicrobial resistance. Herein, a miniaturized, user-friendly device for the electrochemical antibiotic susceptibility study of () has been developed. In contrast to the traditional methods, the designed device has the rapid sensing ability to screen different antibiotics simultaneously, reducing the overall time of diagnosis. Screen-printed electrodes with integrated miniaturized reservoirs with a thermostat were developed. The designed device proffers simultaneous incubator-free culturing and detects antibiotic susceptibility within 6 h, seven times faster than the conventional method. Four antibiotics, namely amoxicillin-clavulanic acid, ciprofloxacin, ofloxacin, and cefpodoxime, were tested against . Tap water and synthetic urine samples were also tested for antibiotic susceptibility. The results show that the device could be used for antibiotic resistance susceptibility testing against with four antibiotics within six hours. The developed rapid, low-cost, user-friendly device will aid in antibiotic screening applications, enable the patient to receive the appropriate treatment, and help to lower the risk of anti-microbial resistance.

Citing Articles

Next-generation rapid phenotypic antimicrobial susceptibility testing.

Reszetnik G, Hammond K, Mahshid S, AbdElFatah T, Nguyen D, Corsini R Nat Commun. 2024; 15(1):9719.

PMID: 39521792 PMC: 11550857. DOI: 10.1038/s41467-024-53930-x.


Efficient Absorbance-Based Assay for Rapid Antibiotic Susceptibility Testing of Enterobacterales.

Axelsson C, Nilson B, Rehnstam-Holm A Antibiotics (Basel). 2024; 13(9).

PMID: 39335025 PMC: 11429340. DOI: 10.3390/antibiotics13090852.

References
1.
Pandey A, Gurbuz Y, Ozguz V, Niazi J, Qureshi A . Graphene-interfaced electrical biosensor for label-free and sensitive detection of foodborne pathogenic E. coli O157:H7. Biosens Bioelectron. 2016; 91:225-231. DOI: 10.1016/j.bios.2016.12.041. View

2.
Jeon H, Khan Z, Barakat E, Park S . Label-Free Electrochemical Microfluidic Chip for the Antimicrobial Susceptibility Testing. Antibiotics (Basel). 2020; 9(6). PMC: 7344617. DOI: 10.3390/antibiotics9060348. View

3.
Behera B, Anil Vishnu G, Chatterjee S, Sitaramgupta V V, Sreekumar N, Nagabhushan A . Emerging technologies for antibiotic susceptibility testing. Biosens Bioelectron. 2019; 142:111552. DOI: 10.1016/j.bios.2019.111552. View

4.
Veloo A, Seme K, Raangs E, Rurenga P, Singadji Z, Wekema-Mulder G . Antibiotic susceptibility profiles of oral pathogens. Int J Antimicrob Agents. 2012; 40(5):450-4. DOI: 10.1016/j.ijantimicag.2012.07.004. View

5.
Viviana Tarditto L, Zon M, Garcia Ovando H, Roberto Vettorazzi N, Javier Arevalo F, Fernandez H . Electrochemical magneto immunosensor based on endogenous β-galactosidase enzyme to determine enterotoxicogenic Escherichia coli F4 (K88) in swine feces using square wave voltammetry. Talanta. 2017; 174:507-513. DOI: 10.1016/j.talanta.2017.06.059. View