This work presents a continuous roll-to-roll electrochemical coating system for producing silver/silver chloride (Ag/AgCl)-coated yarns, and their application in e-textile electrodes for biosignal monitoring. Ag/AgCl is one of the most preferred electrode materials as an interface between the conductive backbone of an electrode and skin. E-textile Ag/AgCl-coated multi-filament nylon yarns offer stable, flexible, and breathable alternatives to standard rigid or flexible film-based Ag/AgCl electrodes. The developed system allows for highly controlled process parameters to achieve stable and uniform AgCl film deposition on Ag-coated nylon yarns. The electrical, electrochemical properties, and morphology of the coated yarns were characterized. Dry electrodes were fabricated and could measure electrocardiogram (ECG) signals with comparable performance to standard gel electrodes. Ag/AgCl e-textile electrodes demonstrated high stability, with low average polarization potential (1.22 mV/min) compared with Ag-coated electrodes (3.79 mV/min), low impedance (below 2 MΩ, 0.1-150 Hz), and are excellent candidates for heart rate detection and monitoring.

Citing Articles

Measuring Surface Electromyography with Textile Electrodes in a Smart Leg Sleeve.

Amitrano F, Coccia A, Pagano G, Biancardi A, Tombolini G, Marsico V Sensors (Basel). 2024; 24(9).

PMID: 38732868 PMC: 11086330. DOI: 10.3390/s24092763.

References
1.
Getzel W, Webster J . Minimizing silver-silver chloride electrode impedance. IEEE Trans Biomed Eng. 1976; 23(1):87-8. DOI: 10.1109/tbme.1976.324626. View

2.
Castrillon R, Perez J, Andrade-Caicedo H . Electrical performance of PEDOT:PSS-based textile electrodes for wearable ECG monitoring: a comparative study. Biomed Eng Online. 2018; 17(1):38. PMC: 5879742. DOI: 10.1186/s12938-018-0469-5. View

3.
Scilingo E, Gemignani A, Paradiso R, Taccini N, Ghelarducci B, De Rossi D . Performance evaluation of sensing fabrics for monitoring physiological and biomechanical variables. IEEE Trans Inf Technol Biomed. 2005; 9(3):345-52. DOI: 10.1109/titb.2005.854506. View

4.
Rattfalt L, Bjorefors F, Nilsson D, Wang X, Norberg P, Ask P . Properties of screen printed electrocardiography smartware electrodes investigated in an electro-chemical cell. Biomed Eng Online. 2013; 12:64. PMC: 3716966. DOI: 10.1186/1475-925X-12-64. View

5.
Rattfalt L, Linden M, Hult P, Berglin L, Ask P . Electrical characteristics of conductive yarns and textile electrodes for medical applications. Med Biol Eng Comput. 2007; 45(12):1251-7. DOI: 10.1007/s11517-007-0266-y. View