Macular Electroretinograms and Contrast Sensitivity As Sensitive Detectors of Early Maculopathy

Overview
Journal Doc Ophthalmol
Specialty Ophthalmology
Date 1986 Nov 15
PMID 3803170
Citations 7
Authors
Affiliations
Soon will be listed here.
Abstract

Eighteen patients with early maculopathies of various etiologies were tested with pattern and focal electroretinograms (macular ERGs), with high (400 cd/M2) and moderate (40 cd/M2) stimulus intensities and a four-alternative forced choice (4AFC) contrast sensitivity test in addition to intensive clinical examinations. High spatial frequency contrast sensitivity loss on the 4AFC test was the most striking and consistent feature of all cases. The only eyes not outside normal contrast sensitivity limits were three in which diagnosis was uncertain and the patients had not recognized any problem, including two marginal solar burns. Maculopathy also substantially reduced macular ERG amplitudes. Criterion scores on these tests separated patients from normals more effectively than other noninvasive procedures and only missed one eye detected by contrast sensitivity. Latencies were affected but the delays were of no clinical significance in the individual case. Stimulus intensity was not critical. The results indicate that contrast sensitivity testing and macular ERGs are very reliable indices of central visual dysfunction at a stage when visible macular changes are too subtle for confident diagnosis. Contrast sensitivity has appeal because of its reliability, objectivity, simplicity, and noninvasive nature. It is equally applicable to children and adults. Pattern and focal ERGs can establish that the visual deficit has a retinal origin and can provide the most reliable objective confirmation.

Citing Articles

Electrophysiological and clinical tests in dry age-related macular degeneration follow-up: differences between mfERG and OCT.

Gonzalez-Garcia E, Vilela C, Navea A, Arnal E, Muriach M, Romero F Doc Ophthalmol. 2016; 133(1):31-9.

PMID: 27290699 DOI: 10.1007/s10633-016-9545-y.


The differential effect of optic nerve disease on pattern and focal electroretinograms.

Veagan , Billson F Doc Ophthalmol. 1987; 65(1):45-55.

PMID: 3665701 DOI: 10.1007/BF00162719.


Electrophysiological evidence that early glaucoma affects foveal vision.

Marx M, Bodis-Wollner I, Lustgarten J, Podos S Doc Ophthalmol. 1987; 67(3):281-301.

PMID: 3447853 DOI: 10.1007/BF00144282.


Long-term follow-up of an ophthalmologist's central serous retinopathy, photocoagulated by sungazing.

Gartner J Doc Ophthalmol. 1987; 66(1):19-33.

PMID: 3428072 DOI: 10.1007/BF00144736.


Simultaneously recorded macular and paramacular ERGs in diseases affecting the central retina.

BAGOLINI B, Porciatti V, Falsini B, Scalia G, Merendino E Doc Ophthalmol. 1988; 68(3-4):273-82.

PMID: 3402316 DOI: 10.1007/BF00156433.


References
1.
Hess R, Baker Jr C . Human pattern-evoked electroretinogram. J Neurophysiol. 1984; 51(5):939-51. DOI: 10.1152/jn.1984.51.5.939. View

2.
CAMPBELL F, Green D . Optical and retinal factors affecting visual resolution. J Physiol. 1965; 181(3):576-93. PMC: 1357668. DOI: 10.1113/jphysiol.1965.sp007784. View

3.
Hess R, Howell E . The threshold contrast sensitivity function in strabismic amblyopia: evidence for a two type classification. Vision Res. 1977; 17(9):1049-55. DOI: 10.1016/0042-6989(77)90009-8. View

4.
Arden G, Jacobson J . A simple grating test for contrast sensitivity: preliminary results indicate value in screening for glaucoma. Invest Ophthalmol Vis Sci. 1978; 17(1):23-32. View

5.
Korth M . Pattern-evoked responses and luminance-evoked responses in the human electroretinogram. J Physiol. 1983; 337:451-69. PMC: 1199118. DOI: 10.1113/jphysiol.1983.sp014635. View