» Articles » PMID: 38005638

Unobstructive Heartbeat Monitoring of Sleeping Infants and Young Children Using Sheet-Type PVDF Sensors

Overview
Journal Sensors (Basel)
Publisher MDPI
Specialty Biotechnology
Date 2023 Nov 25
PMID 38005638
Authors
Affiliations
Soon will be listed here.
Abstract

Techniques for noninvasively acquiring the vital information of infants and young children are considered very useful in the fields of healthcare and medical care. An unobstructive measurement method for sleeping infants and young children under the age of 6 years using a sheet-type vital sensor with a polyvinylidene fluoride (PVDF) pressure-sensitive layer is demonstrated. The signal filter conditions to obtain the ballistocardiogram (BCG) and phonocardiogram (PCG) are discussed from the waveform data of infants and young children. The difference in signal processing conditions was caused by the physique of the infants and young children. The peak-to-peak interval (PPI) extracted from the BCG or PCG during sleep showed an extremely high correlation with the R-to-R interval (RRI) extracted from the electrocardiogram (ECG). The vital changes until awakening in infants monitored using a sheet sensor were also investigated. In infants under one year of age that awakened spontaneously, the distinctive vital changes during awakening were observed. Understanding the changes in the heartbeat and respiration signs of infants and young children during sleep is essential for improving the accuracy of abnormality detection by unobstructive sensors.

References
1.
Gulzar Ahmad S, Iqbal T, Javaid A, Ullah Munir E, Kirn N, Jan S . Sensing and Artificial Intelligent Maternal-Infant Health Care Systems: A Review. Sensors (Basel). 2022; 22(12). PMC: 9228894. DOI: 10.3390/s22124362. View

2.
Watanabe K, Watanabe T, Watanabe H, Ando H, Ishikawa T, Kobayashi K . Noninvasive measurement of heartbeat, respiration, snoring and body movements of a subject in bed via a pneumatic method. IEEE Trans Biomed Eng. 2005; 52(12):2100-7. DOI: 10.1109/TBME.2005.857637. View

3.
Vehkaoja A, Kontunen A, Lekkala J . Effects of sensor type and sensor location on signal quality in bed mounted ballistocardiographic heart rate and respiration monitoring. Annu Int Conf IEEE Eng Med Biol Soc. 2016; 2015:4383-6. DOI: 10.1109/EMBC.2015.7319366. View

4.
Niizeki K, Nishidate I, Uchida K, Kuwahara M . Unconstrained cardiorespiratory and body movement monitoring system for home care. Med Biol Eng Comput. 2006; 43(6):716-24. DOI: 10.1007/BF02430948. View

5.
Balali P, Rabineau J, Hossein A, Tordeur C, Debeir O, van de Borne P . Investigating Cardiorespiratory Interaction Using Ballistocardiography and Seismocardiography-A Narrative Review. Sensors (Basel). 2022; 22(23). PMC: 9737480. DOI: 10.3390/s22239565. View