Automated Remodelling of Connectors in Fixed Partial Dentures

Overview
Journal Dent J (Basel)
Specialty Dentistry
Date 2023 Nov 24
PMID 37999016
Authors
Affiliations
Soon will be listed here.
Abstract

In this study, an approach for automated parametric remodelling of the connector cross-sectional area in a CAD model of a given fixed partial denture (FPD) geometry was developed and then applied to a 4-unit FPD. The remodelling algorithm was implemented using Rhinoceros and the Grasshopper plugin. The generated CAD models were used to perform a finite element analysis with Ansys to analyse the stress distribution in an implant-supported 4-unit FPD for different connector designs. The results showed that the type of connector adjustment matters and that the resulting stress can be significantly different even for connectors with the same cross-sectional area. For tensile stresses, a reduction in the connector cross-sectional area from the gingival side showed the highest influence on each connector type. It can be concluded that the developed algorithm is suitable for automatic connector detection and adjustment.

Citing Articles

Automated Support Generation for Fixed Partial Dentures and Impact of Bone Loss, Bone Quality and Support Types: Parametric Cad and Finite Element Analysis.

Jemaa H, Eisenburger M, Greuling A Dent J (Basel). 2024; 12(12).

PMID: 39727451 PMC: 11674901. DOI: 10.3390/dj12120394.

References
1.
da Silva L, de Lima E, de Paula Miranda R, Favero S, Lohbauer U, Cesar P . Dental ceramics: a review of new materials and processing methods. Braz Oral Res. 2017; 31(suppl 1):e58. DOI: 10.1590/1807-3107BOR-2017.vol31.0058. View

2.
Dittmer M, Kohorst P, Borchers L, Schwestka-Polly R, Stiesch M . Stress analysis of an all-ceramic FDP loaded according to different occlusal concepts. J Oral Rehabil. 2010; 38(4):278-85. DOI: 10.1111/j.1365-2842.2010.02147.x. View

3.
Bahat Z, Mahmood D, Vult von Steyern P . Fracture strength of three-unit fixed partial denture cores (Y-TZP) with different connector dimension and design. Swed Dent J. 2009; 33(3):149-59. View

4.
Kim W, Li X, Bidra A . Clinical outcomes of implant-supported monolithic zirconia crowns and fixed partial dentures: A systematic review. J Prosthodont. 2022; 32(2):102-107. DOI: 10.1111/jopr.13575. View

5.
Rand A, Kohorst P, Greuling A, Borchers L, Stiesch M . Stress Distribution in All-Ceramic Posterior 4-Unit Fixed Dental Prostheses Supported in Different Ways: Finite Element Analysis. Implant Dent. 2016; 25(4):485-91. DOI: 10.1097/ID.0000000000000429. View