A Pilot Study Examining the Dielectric Response of Human Forearm Tissues

Overview
Specialty Biotechnology
Date 2023 Nov 24
PMID 37998136
Authors
Affiliations
Soon will be listed here.
Abstract

This work aims to describe the dielectric behaviors of four main tissues in the human forearm using mathematical modelling, including fat, muscle, blood and bone. Multi-frequency bioimpedance analysis (MF-BIA) was initially performed using the finite element method (FEM) with a 3D forearm model to estimate impedance spectra from 10 kHz to 1 MHz, followed by a pilot study involving two healthy subjects to characterize the response of actual forearm tissues from 1 kHz to 349 kHz. Both the simulation and experimental results were fitted to a single-dispersion Cole model (SDCM) and a multi-dispersion Cole model (MDCM) to determine the Cole parameters for each tissue. Cole-type responses of both simulated and actual human forearms were observed. A paired -test based on the root mean squared error (RMSE) values indicated that both Cole models performed comparably in fitting both simulated and measured bioimpedance data. However, MDCM exhibited higher accuracy, with a correlation coefficient (R) of 0.99 and 0.89, RMSE of 0.22 Ω and 0.56 Ω, mean difference (mean ± standard deviation) of 0.00 ± 0.23 Ω and -0.28 ± 0.23 Ω, and mean absolute error (MAE) of 0.0007 Ω and 0.2789 Ω for the real part and imaginary part of impedance, respectively. Determining the electrical response of multi-tissues can be helpful in developing physiological monitoring of an organ or a section of the human body through MF-BIA and hemodynamic monitoring by filtering out the impedance contributions from the surrounding tissues to blood-flow-induced impedance variations.

References
1.
Schwan H . Electrical properties of tissue and cell suspensions. Adv Biol Med Phys. 1957; 5:147-209. DOI: 10.1016/b978-1-4832-3111-2.50008-0. View

2.
Jebb S, Siervo M, Murgatroyd P, Evans S, Fruhbeck G, Prentice A . Validity of the leg-to-leg bioimpedance to estimate changes in body fat during weight loss and regain in overweight women: a comparison with multi-compartment models. Int J Obes (Lond). 2006; 31(5):756-62. DOI: 10.1038/sj.ijo.0803475. View

3.
Freeborn T, Maundy B, Elwakil A . Extracting the parameters of the double-dispersion Cole bioimpedance model from magnitude response measurements. Med Biol Eng Comput. 2014; 52(9):749-58. DOI: 10.1007/s11517-014-1175-5. View

4.
Yu Y, Anand G, Lowe A, Zhang H, Kalra A . Towards Estimating Arterial Diameter Using Bioimpedance Spectroscopy: A Computational Simulation and Tissue Phantom Analysis. Sensors (Basel). 2022; 22(13). PMC: 9268936. DOI: 10.3390/s22134736. View

5.
Trazzi S, Omboni S, Santucciu C, Parati G, Mancia G . Variability in arterial diameter and compliance: compliance modulation reserve. J Hypertens Suppl. 1992; 10(6):S41-3. View