» Articles » PMID: 37990543

Preferred Strength of Noise Reduction for Normally Hearing and Hearing-Impaired Listeners

Overview
Journal Trends Hear
Date 2023 Nov 22
PMID 37990543
Authors
Affiliations
Soon will be listed here.
Abstract

Preference for noise reduction (NR) strength differs between individuals. The purpose of this study was (1) to investigate whether hearing loss influences this preference, (2) to find the number of distinct settings required to classify participants in similar groups based on their preference for NR strength, and (3) to estimate the number of paired comparisons needed to predict to which preference group a participant belongs. A paired comparison paradigm was used in which participants listened to pairs of speech-in-noise stimuli processed by NR with 10 different strength settings. Participants indicated their preferred sound sample. The 30 participants were divided into three groups according to hearing status (normal hearing, mild hearing loss, and moderate hearing loss). The results showed that (1) participants with moderate hearing loss preferred stronger NR than participants with normal hearing; (2) cluster analysis based solely on the preference for NR strength showed that the data could be described well by dividing the participants into three preference clusters; (3) the appropriate cluster membership could be found with 15 paired comparisons. We conclude that on average, a higher hearing loss is related to a preference for stronger NR, at least for our NR algorithm and our participants. The results show that it might be possible to use a limited set of pre-set NR strengths that can be chosen clinically. For our NR one might use three settings: no NR, intermediate NR, and strong NR. Paired comparisons might be used to find the optimal one of the three settings.

References
1.
Volker C, Ernst S, Kollmeier B . Hearing aid fitting and fine-tuning based on estimated individual traits. Int J Audiol. 2016; 57(sup3):S139-S145. DOI: 10.1080/14992027.2016.1257163. View

2.
Arehart K, Souza P, Kates J, Lunner T, Pedersen M . Relationship Among Signal Fidelity, Hearing Loss, and Working Memory for Digital Noise Suppression. Ear Hear. 2015; 36(5):505-16. PMC: 4549215. DOI: 10.1097/AUD.0000000000000173. View

3.
Neher T . Relating hearing loss and executive functions to hearing aid users' preference for, and speech recognition with, different combinations of binaural noise reduction and microphone directionality. Front Neurosci. 2014; 8:391. PMC: 4255521. DOI: 10.3389/fnins.2014.00391. View

4.
Recker K, Goyette A, Galster J . Preferences for digital noise reduction and microphone mode settings in hearing-impaired listeners with low and high tolerances for background noise. Int J Audiol. 2019; 59(2):90-100. DOI: 10.1080/14992027.2019.1671615. View

5.
Luts H, Eneman K, Wouters J, Schulte M, Vormann M, Buechler M . Multicenter evaluation of signal enhancement algorithms for hearing aids. J Acoust Soc Am. 2010; 127(3):1491-505. DOI: 10.1121/1.3299168. View