Clinical Application and Follow-up of Electrocautery-enhanced Lumen-apposing Metal Stents for Endoscopic Ultrasonography-guided Interventions

Overview
Journal Ann Med
Publisher Informa Healthcare
Specialty General Medicine
Date 2023 Nov 15
PMID 37967551
Authors
Affiliations
Soon will be listed here.
Abstract

The lumen-apposing metal stent (LAMS) is a new device that expands the scope of gastrointestinal intervention under endoscopy. LAMS was initially used for the treatment of pancreatic fluid collections (PFCs), but is increasingly being used off-label. The electrocautery system simplifies the deployment of LAMS, making it more suitable for off-label situations. The short-term results of electrocautery-enhanced lumen-apposing metal stents (ECE-LAMS) are satisfactory; however, the long-term follow-up results must be evaluated. The aim of this article is to review the expanded clinical application of ECE-LAMS, the clinical value of on-label and off-label use, and follow-up results. After searching in PubMed and Web of Science databases using 'electrocautery-enhanced lumen-apposing metal stents' and 'endoscopic ultrasonography (EUS) -guided interventions' as keywords, studies related were compiled and examined. ECE-LAMS are widely used for on-label and off-label situations. The short-term and long-term results of ECE-LAMS are satisfactory, but there are still some studies that do not agree with this viewpoint. The clinical application of ECE-LAMS is relatively safe and reliable but more well-designed randomized trials and prospective studies are needed to evaluate the impact of this technology on therapeutic EUS, to improve the safety and success rate of EUS-guided LAMS implantation, and to expand its application in other indications.

Citing Articles

Endoscopic Drainage of Intra-abdominal Fluid Collections and Abscesses.

Chittajallu V, Adoor D, Faulx A Semin Intervent Radiol. 2024; 41(5):455-459.

PMID: 39664219 PMC: 11631364. DOI: 10.1055/s-0044-1791723.


Role of endoscopic ultrasound-guided biliary drainage for palliation of malignant biliary obstruction.

Singh S, Chandan S, Facciorusso A World J Gastrointest Surg. 2024; 16(8):2369-2373.

PMID: 39220057 PMC: 11362943. DOI: 10.4240/wjgs.v16.i8.2369.

References
1.
Antonelli G, Kovacevic B, Karstensen J, Kalaitzakis E, Vanella G, Hassan C . Endoscopic ultrasound-guided gastro-enteric anastomosis: A systematic review and meta-analysis. Dig Liver Dis. 2020; 52(11):1294-1301. DOI: 10.1016/j.dld.2020.04.021. View

2.
Fabbri C, Coluccio C, Binda C, Fugazza A, Anderloni A, Tarantino I . Lumen-apposing metal stents: How far are we from standardization? An Italian survey. Endosc Ultrasound. 2021; 11(1):59-67. PMC: 8887041. DOI: 10.4103/EUS-D-21-00015. View

3.
Khan S, Chandran S, Chin J, Karim S, Mangira D, Nasr M . Drainage of pancreatic fluid collections using a lumen-apposing metal stent with an electrocautery-enhanced delivery system. J Gastroenterol Hepatol. 2021; 36(12):3395-3401. DOI: 10.1111/jgh.15658. View

4.
Mekheal N, Aslanian H, Kesar V, Jamidar P, Muniraj T . Ileosigmoid Anastomotic Perforation Three Weeks After Placement of Lumen-Apposing Metal Stent (LAMS). Cureus. 2022; 13(12):e20565. PMC: 8772393. DOI: 10.7759/cureus.20565. View

5.
Nagem R, Lazaro-da-Silva A, de Oliveira R, Morato V . Gallstone-related complications after Roux-en-Y gastric bypass: a prospective study. Hepatobiliary Pancreat Dis Int. 2012; 11(6):630-5. DOI: 10.1016/s1499-3872(12)60236-7. View