» Articles » PMID: 37888738

Retrospective Motion Artifact Reduction by Spatial Scaling of Liver Diffusion-Weighted Images

Overview
Journal Tomography
Publisher MDPI
Specialty Radiology
Date 2023 Oct 27
PMID 37888738
Authors
Affiliations
Soon will be listed here.
Abstract

Cardiac motion causes unpredictable signal loss in respiratory-triggered diffusion-weighted magnetic resonance imaging (DWI) of the liver, especially inside the left lobe. The left liver lobe may thus be frequently neglected in the clinical evaluation of liver DWI. In this work, a data-driven algorithm that relies on the statistics of the signal in the left liver lobe to mitigate the motion-induced signal loss is presented. The proposed data-driven algorithm utilizes the exclusion of severely corrupted images with subsequent spatially dependent image scaling based on a signal-loss model to correctly combine the multi-average diffusion-weighted images. The signal in the left liver lobe is restored and the liver signal is more homogeneous after applying the proposed algorithm. Furthermore, overestimation of the apparent diffusion coefficient (ADC) in the left liver lobe is reduced. The proposed algorithm can therefore contribute to reduce the motion-induced bias in DWI of the liver and help to increase the diagnostic value of DWI in the left liver lobe.

Citing Articles

Clinical Applications of Artificial Intelligence in Medical Imaging and Image Processing-A Review.

Obuchowicz R, Strzelecki M, Piorkowski A Cancers (Basel). 2024; 16(10).

PMID: 38791949 PMC: 11120567. DOI: 10.3390/cancers16101870.

References
1.
Dyvorne H, Galea N, Nevers T, Fiel M, Carpenter D, Wong E . Diffusion-weighted imaging of the liver with multiple b values: effect of diffusion gradient polarity and breathing acquisition on image quality and intravoxel incoherent motion parameters--a pilot study. Radiology. 2012; 266(3):920-9. PMC: 3579172. DOI: 10.1148/radiol.12120686. View

2.
Alexander D, Dyrby T, Nilsson M, Zhang H . Imaging brain microstructure with diffusion MRI: practicality and applications. NMR Biomed. 2017; 32(4):e3841. DOI: 10.1002/nbm.3841. View

3.
Nasu K, Kuroki Y, Sekiguchi R, Kazama T, Nakajima H . Measurement of the apparent diffusion coefficient in the liver: is it a reliable index for hepatic disease diagnosis?. Radiat Med. 2006; 24(6):438-44. DOI: 10.1007/s11604-006-0053-y. View

4.
Harris C, Millman K, van der Walt S, Gommers R, Virtanen P, Cournapeau D . Array programming with NumPy. Nature. 2020; 585(7825):357-362. PMC: 7759461. DOI: 10.1038/s41586-020-2649-2. View

5.
Zhang Y, Pena-Nogales O, Holmes J, Hernando D . Motion-robust and blood-suppressed M1-optimized diffusion MR imaging of the liver. Magn Reson Med. 2019; 82(1):302-311. DOI: 10.1002/mrm.27735. View