» Articles » PMID: 3787553

Influence of Knowledge of Peak Flow on Self Assessment of Asthma: Studies with a Coded Peak Flow Meter

Overview
Journal Thorax
Date 1986 Sep 1
PMID 3787553
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

A portable peak flow meter based on a turbine transducer that can display results in code has been developed. Its performance compares well with the Wright peak flow meter. Records of subjective self assessment of asthma on a visual analogue scale and of peak flow (PEF) were compared in 12 subjects with asthma. PEF measurements were made with a coded meter for two weeks and an uncoded meter for two weeks in random order. The correlation between visual analogue scale score and PEF was invariably stronger when PEF was known. Changes in perception of asthma were measured by comparing the slopes and relative positions of the regressions of visual analogue on PEF. When PEF was uncoded awareness of asthma was significantly increased in five patients, predominantly those whose perception was poorest while they were using the coded meter, and decreased in only one patient. In two patients the results were unsuitable for this type of analysis. Knowledge of PEF therefore may influence subjective self assessment in patients with bronchial asthma. For objective studies of symptoms of asthma, PEF readings should be unknown to the patient. Perception of asthma may, however, be improved in patients with poor ability to detect changes in bronchial calibre by uncoded measurement of peak flow at home.

Citing Articles

Current perspectives on symptom perception in asthma: a biomedical and psychological review.

Rietveld S, Brosschot J Int J Behav Med. 2005; 6(2):120-34.

PMID: 16250683 DOI: 10.1207/s15327558ijbm0602_2.


Accuracy of perception of severity of asthma: patients treated in general practice.

Kendrick A, Higgs C, Whitfield M, Laszlo G BMJ. 1993; 307(6901):422-4.

PMID: 8374455 PMC: 1678402. DOI: 10.1136/bmj.307.6901.422.


Chronic asthma and hypnotherapy.

Higgs C J R Soc Med. 1989; 82(7):446.

PMID: 2585433 PMC: 1292225. DOI: 10.1177/014107688908200732.


British Thoracic Society summer meeting. 11-13 July 1990, Birmingham. Abstracts.

Thorax. 1990; 45(10):779-824.

PMID: 2247874 PMC: 462743. DOI: 10.1136/thx.45.10.779.


Alternative and complementary medicine for asthma.

Lane D, Lane T Thorax. 1991; 46(11):787-97.

PMID: 1771600 PMC: 1021030. DOI: 10.1136/thx.46.11.787.

References
1.
Rubinfeld A, PAIN M . Relationship between bronchial reactivity, airway caliber, and severity of asthma. Am Rev Respir Dis. 1977; 115(3):381-7. DOI: 10.1164/arrd.1977.115.3.381. View

2.
Ormerod L, Stableforth D . Asthma mortality in Birmingham 1975-7: 53 deaths. Br Med J. 1980; 280(6215):687-90. PMC: 1600791. DOI: 10.1136/bmj.280.6215.687. View

3.
Oldham H, Bevan M, McDermott M . Comparison of the new miniature Wright peak flow meter with the standard Wright peak flow meter. Thorax. 1979; 34(6):807-9. PMC: 471201. DOI: 10.1136/thx.34.6.807. View

4.
Shephard R . Some observations on peak expiratory flow. Thorax. 1962; 17:39-48. PMC: 1018668. DOI: 10.1136/thx.17.1.39. View

5.
Chowienczyk P, Lawson C . Pocket-sized device for measuring forced expiratory volume in one second and forced vital capacity. Br Med J (Clin Res Ed). 1982; 285(6334):15-7. PMC: 1499098. DOI: 10.1136/bmj.285.6334.15. View