» Articles » PMID: 37872427

Intra-abdominal Laparoscopic Assessment of Organs Perfusion Using Imaging Photoplethysmography

Overview
Journal Surg Endosc
Publisher Springer
Date 2023 Oct 23
PMID 37872427
Authors
Affiliations
Soon will be listed here.
Abstract

Background: An objective evaluation of the functional state and viability of biological tissues during minimally invasive surgery remains unsolved task. Various non-contact methods for evaluating perfusion during laparoscopic surgery are discussed in the literature, but so far there have been no reports of their use in clinical settings.

Methods And Patients: Imaging photoplethysmography (iPPG) is a new method for quantitative assessment of perfusion distribution along the tissue. This is the first study in which we demonstrate successful use of iPPG to assess perfusion of organs during laparoscopic surgery in an operation theater. We used a standard rigid laparoscope connected to a standard digital monochrome camera, and abdominal organs were illuminated by green light. A distinctive feature is the synchronous recording of video frames and electrocardiogram with subsequent correlation data processing. During the laparoscopically assisted surgeries in nine cancer patients, the gradient of perfusion of the affected organs was evaluated. In particular, measurements were carried out before preparing a part of the intestine or stomach for resection, after anastomosis, or during physiological tests.

Results: The spatial distribution of perfusion and its changes over time were successfully measured in all surgical cases. In particular, perfusion gradient of an intestine before resection was visualized and quantified by our iPPG laparoscope in all respective cases. It was also demonstrated that systemic administration of norepinephrine leads to a sharper gradient between well and poorly perfused areas of the colon. In four surgical cases, we have shown capability of the laparoscopic iPPG system for intra-abdominal assessment of perfusion in the anastomosed organs. Moreover, good repeatability of continuous long-term measurements of tissue perfusion inside the abdominal cavity was experimentally demonstrated.

Conclusion: Our study carried out in real clinical settings has shown that iPPG laparoscope is feasible for intra-abdominal visualization and quantitative assessment of perfusion distribution.

Citing Articles

Potential Probes for Targeted Intraoperative Fluorescence Imaging in Gastric Cancer.

Martinelli S, Fortuna L, Coratti F, Passagnoli F, Amedei A, Cianchi F Cancers (Basel). 2025; 16(24.

PMID: 39766041 PMC: 11675003. DOI: 10.3390/cancers16244141.

References
1.
Urbanavicius L, Pattyn P, Van de Putte D, Venskutonis D . How to assess intestinal viability during surgery: A review of techniques. World J Gastrointest Surg. 2011; 3(5):59-69. PMC: 3110878. DOI: 10.4240/wjgs.v3.i5.59. View

2.
Miyashiro I, Kishi K, Yano M, Tanaka K, Motoori M, Ohue M . Laparoscopic detection of sentinel node in gastric cancer surgery by indocyanine green fluorescence imaging. Surg Endosc. 2010; 25(5):1672-6. DOI: 10.1007/s00464-010-1405-3. View

3.
Diana M, Agnus V, Halvax P, Liu Y, Dallemagne B, Schlagowski A . Intraoperative fluorescence-based enhanced reality laparoscopic real-time imaging to assess bowel perfusion at the anastomotic site in an experimental model. Br J Surg. 2015; 102(2):e169-76. DOI: 10.1002/bjs.9725. View

4.
Schols R, Bouvy N, M van Dam R, Stassen L . Advanced intraoperative imaging methods for laparoscopic anatomy navigation: an overview. Surg Endosc. 2012; 27(6):1851-9. DOI: 10.1007/s00464-012-2701-x. View

5.
Han Z, Zhang A, Wang X, Sun Z, Wang M, Xie T . In vivo use of hyperspectral imaging to develop a noncontact endoscopic diagnosis support system for malignant colorectal tumors. J Biomed Opt. 2016; 21(1):16001. DOI: 10.1117/1.JBO.21.1.016001. View