» Articles » PMID: 37869330

Coronary Computed Tomography Angiography Analysis Using Artificial Intelligence for Stenosis Quantification and Stent Segmentation: a Multicenter Study

Overview
Specialty Radiology
Date 2023 Oct 23
PMID 37869330
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Accurate interpretation of coronary computed tomography angiography (CCTA) is a labor-intensive and expertise-driven endeavor, as inexperienced readers may inadvertently overestimate stenosis severity. Recent artificial intelligence (AI) advances in medical imaging present compelling prospects for auxiliary diagnostic tools in CCTA. This study aimed to externally validate an AI-assisted analysis system capable of rapidly evaluating stenosis severity, exploring its potential integration into routine clinical workflows.

Methods: This multicenter study consisted of an internal and external cohort of patients who underwent CCTA scans between April 2017 and February 2023. CCTA scans were evaluated using Coronary Artery Disease Reporting and Data System (CAD-RADS) scores to determine stenosis severity, while ground-truth stents were manually annotated by expert readers. The InferRead CT Heart (version 1.6; Infervision Medical Technology Co., Ltd., Beijing, China), which incorporates AI-assisted coronary artery stenosis quantification and automatic stent segmentation, was employed for CCTA scan analysis. AI-based stenosis assessment performance was determined using sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV), while the AI-based stent segmentation overlap was assessed using the Dice similarity coefficient (DSC).

Results: For ≥50% stenosis diagnoses, the AI system attained per-patient sensitivity, specificity, PPV, and NPV surpassing 90.0% for the internal dataset; for the external dataset, the per-patient values were 88.0% [95% confidence interval (CI): 81.0-94.4%], 94.5% (95% CI: 90.7-97.6%), 90.0% (95% CI: 83.3-95.6%), and 93.4% (95% CI: 89.2-96.8%), respectively. For ≥70% stenosis diagnoses, the per-patient values on the internal dataset were 94.2% (95% CI: 89.2-98.1%), 95.8% (95% CI: 94.1-97.4%), 80.8% (95% CI: 73.5-87.7%), and 98.9% (95% CI: 97.9-99.6%), respectively; for the external dataset, the per-patient values were 91.9% (95% CI: 82.6-100.0%), 97.3% (95% CI: 94.9-99.1%), 85.0% (95% CI: 72.5-94.6%), and 98.6% (95% CI: 96.8-100.0%), respectively. Regarding CAD-RADS categorization, the Cohen kappa was 0.75 and 0.81 for the internal per-patient and per-vessel basis, respectively, and 0.72 and 0.76 for the external per-patient and per-vessel basis, respectively. The DSC for stent segmentation was 0.96±0.06.

Conclusions: The AI-assisted analysis system for CCTA interpretation exhibited exceptional proficiency in stenosis quantification and stent segmentation, indicating that AI holds considerable potential in advancing CCTA postprocessing techniques.

Citing Articles

Enhancing coronary artery plaque analysis via artificial intelligence-driven cardiovascular computed tomography.

Xia J, Bachour K, Suleiman A, Roberts J, Sayed S, Cho G Ther Adv Cardiovasc Dis. 2024; 18:17539447241303399.

PMID: 39625215 PMC: 11615974. DOI: 10.1177/17539447241303399.


Artificial Intelligence for Identification of Images with Active Bleeding in Mesenteric and Celiac Arteries Angiography.

Barash Y, Livne A, Klang E, Sorin V, Cohen I, Khaitovich B Cardiovasc Intervent Radiol. 2024; 47(6):785-792.

PMID: 38530394 PMC: 11164777. DOI: 10.1007/s00270-024-03689-x.

References
1.
Newby D, Adamson P, Berry C, Boon N, Dweck M, Flather M . Coronary CT Angiography and 5-Year Risk of Myocardial Infarction. N Engl J Med. 2018; 379(10):924-933. DOI: 10.1056/NEJMoa1805971. View

2.
Nakanishi R, Motoyama S, Leipsic J, Budoff M . How accurate is atherosclerosis imaging by coronary computed tomography angiography?. J Cardiovasc Comput Tomogr. 2019; 13(5):254-260. DOI: 10.1016/j.jcct.2019.06.005. View

3.
Dey D, Slomka P, Leeson P, Comaniciu D, Shrestha S, Sengupta P . Artificial Intelligence in Cardiovascular Imaging: JACC State-of-the-Art Review. J Am Coll Cardiol. 2019; 73(11):1317-1335. PMC: 6474254. DOI: 10.1016/j.jacc.2018.12.054. View

4.
Abbara S, Blanke P, Maroules C, Cheezum M, Choi A, Han B . SCCT guidelines for the performance and acquisition of coronary computed tomographic angiography: A report of the society of Cardiovascular Computed Tomography Guidelines Committee: Endorsed by the North American Society for Cardiovascular Imaging.... J Cardiovasc Comput Tomogr. 2016; 10(6):435-449. DOI: 10.1016/j.jcct.2016.10.002. View

5.
Lu M, Meyersohn N, Mayrhofer T, Bittner D, Emami H, Puchner S . Central Core Laboratory versus Site Interpretation of Coronary CT Angiography: Agreement and Association with Cardiovascular Events in the PROMISE Trial. Radiology. 2017; 287(1):87-95. PMC: 5881637. DOI: 10.1148/radiol.2017172181. View