» Articles » PMID: 37868722

Successful Reconstruction of the Rat Ureter by a Syngeneic Collagen Tube with a Cardiomyocyte Sheet

Overview
Journal Regen Ther
Date 2023 Oct 23
PMID 37868722
Authors
Affiliations
Soon will be listed here.
Abstract

Introduction: Ureteral injuries require surgical intervention as they lead to loss of renal function. The current reconstructive techniques for long ureteral defects are problematic. Consequently, this study aimed to reconstruct the ureter in a rat model using subcutaneously prepared autologous collagen tubes (Biotubes).

Methods: The lower ureter of LEW/SsNSlc rats was ligated to dilate the ureter to make anastomosis easier, and reconstruction was performed six days later by anastomosing the dilated ureter and bladder with a Biotube that was prepared subcutaneously in syngeneic rats. Some rats underwent left nephrectomy and ureter reconstruction simultaneously as negative controls to evaluate the effects of urine flow on patency. The other rats were divided into three groups as follows: a group in which the ureter was reconstructed with the Biotube alone, a group in which cardiomyocyte sheets made from the neonatal hearts of syngeneic rats were wrapped around the Biotube, and a group in which an adipose-derived stem cell sheets made from the inguinal fat of adult syngeneic rats were wrapped. Contrast-enhanced computed tomography and pathological evaluations were performed two weeks after reconstruction.

Result: In the Biotube alone group, all tubes were occluded and hydronephrosis developed, whereas the urothelium regenerated beyond the anastomosis when the left kidney was not removed, suggesting that urothelial epithelial spread occurred with urinary flow. The patency of the ureteral lumen was obtained in some rats in the cardiomyocyte sheet covered group, whereas stricture or obstruction of the reconstructed ureter was observed in all rats in the other groups. Pathological evaluation revealed a layered urothelial structure in the cardiomyocyte sheet covered group, although only a small amount of cardiomyocyte sheets remained.

Conclusion: Urinary flow may support the epithelial spread of the urothelium into the reconstructed ureter. Neonatal rat cardiomyocyte sheets supported the patency of the regenerated ureter with a layered urothelium.

References
1.
Nakayama Y, Kaneko Y, Okumura N, Terazawa T . Initial 3-year results of first human use of an in-body tissue-engineered autologous "Biotube" vascular graft for hemodialysis. J Vasc Access. 2019; 21(1):110-115. DOI: 10.1177/1129729819852550. View

2.
Iimori Y, Iwai R, Nagatani K, Inoue Y, Funayama-Iwai M, Okamoto M . Urinary bladder reconstruction using autologous collagenous connective tissue membrane "Biosheet®" induced by in-body tissue architecture: A pilot study. Regen Ther. 2021; 15:274-280. PMC: 7770416. DOI: 10.1016/j.reth.2020.10.006. View

3.
Nakayama Y, Ishibashi-Ueda H, Takamizawa K . In vivo tissue-engineered small-caliber arterial graft prosthesis consisting of autologous tissue (biotube). Cell Transplant. 2004; 13(4):439-49. DOI: 10.3727/000000004783983828. View

4.
Sekine H, Shimizu T, Yang J, Kobayashi E, Okano T . Pulsatile myocardial tubes fabricated with cell sheet engineering. Circulation. 2006; 114(1 Suppl):I87-93. DOI: 10.1161/CIRCULATIONAHA.105.000273. View

5.
Yoshimura H, Muneta T, Nimura A, Yokoyama A, Koga H, Sekiya I . Comparison of rat mesenchymal stem cells derived from bone marrow, synovium, periosteum, adipose tissue, and muscle. Cell Tissue Res. 2006; 327(3):449-62. DOI: 10.1007/s00441-006-0308-z. View