» Articles » PMID: 3786773

Quantitative CT Applications: Comparison of Current Scanners

Overview
Journal Radiology
Specialty Radiology
Date 1987 Jan 1
PMID 3786773
Citations 18
Authors
Affiliations
Soon will be listed here.
Abstract

Quantitative computed tomography (QCT) has been used with variable success to measure the density of lung nodules, bone, and kidney stones and to determine volumes of tumor. Commercially available CT scanners vary in their ability to quantify high-atomic-number (high-Z) and low-Z components accurately and reproducibly. Sixteen models of CT scanners from eight manufacturers were compared as to their capability for QCT. Field uniformity was determined in phantoms simulating the human torso. For high-Z (250 HU) materials, the difference in CT numbers from the center to a radial distance of 13 cm ranged from 1 to 50 HU (mean, 15 HU); for water, the range was 0-15 HU. Accuracy of computed radiographic localizer systems ranged from +/- 0.5 to +/- 2.0 mm without gantry angulation and up to +/- 4 mm with an angled gantry. A variety of artifacts also reduced QCT accuracy and reproducibility. Thus, not all CT scanners are equally suited to QCT, and results on one machine may not be comparable to those of another unless correction factors are used.

Citing Articles

Establishing the effect of computed tomography reconstruction kernels on the measure of bone mineral density in opportunistic osteoporosis screening.

Matheson B, Boyd S Sci Rep. 2025; 15(1):5449.

PMID: 39953113 PMC: 11828980. DOI: 10.1038/s41598-025-88551-x.


Influence of image reconstruction kernel on computed tomography-based finite element analysis in the clinical opportunistic screening of osteoporosis-A preliminary result.

Jiang C, Jin D, Ni M, Zhang Y, Yuan H Front Endocrinol (Lausanne). 2023; 14:1076990.

PMID: 36936156 PMC: 10014549. DOI: 10.3389/fendo.2023.1076990.


Standardization and Quantitative Imaging With Photon-Counting Detector CT.

McCollough C, Rajendran K, Leng S Invest Radiol. 2023; 58(7):451-458.

PMID: 36728452 PMC: 10272018. DOI: 10.1097/RLI.0000000000000948.


Quantitative Computed Tomography Protocols Affect Material Mapping and Quantitative Computed Tomography-Based Finite-Element Analysis Predicted Stiffness.

Giambini H, Dragomir-Daescu D, Nassr A, Yaszemski M, Zhao C J Biomech Eng. 2016; 138(9).

PMID: 27428281 PMC: 4967881. DOI: 10.1115/1.4034172.


The Effect of Quantitative Computed Tomography Acquisition Protocols on Bone Mineral Density Estimation.

Giambini H, Dragomir-Daescu D, Huddleston P, Camp J, An K, Nassr A J Biomech Eng. 2015; 137(11):114502.

PMID: 26355694 PMC: 4844109. DOI: 10.1115/1.4031572.