Komninou M, Seiler T, Enzmann V
Int Ophthalmol. 2024; 44(1):132.
PMID: 38478103
PMC: 10937779.
DOI: 10.1007/s10792-024-03057-1.
Akpek E, Aldave A, Amescua G, Colby K, Cortina M, de la Cruz J
Transl Vis Sci Technol. 2023; 12(8):9.
PMID: 37561510
PMC: 10431210.
DOI: 10.1167/tvst.12.8.9.
Gupta S, Mahalingam K, Singh A, Selvan H, Somarajan B, Gupta V
Indian J Ophthalmol. 2022; 70(7):2571-2577.
PMID: 35791159
PMC: 9426191.
DOI: 10.4103/ijo.IJO_317_22.
Muench S, Roellig M, Balzani D
Biomech Model Mechanobiol. 2021; 21(2):401-418.
PMID: 34928468
PMC: 8940849.
DOI: 10.1007/s10237-021-01541-6.
Formisano N, van der Putten C, Grant R, Sahin G, Truckenmuller R, Bouten C
Adv Healthc Mater. 2021; 10(20):e2100972.
PMID: 34369098
PMC: 11468718.
DOI: 10.1002/adhm.202100972.
Collagen analogs with phosphorylcholine are inflammation-suppressing scaffolds for corneal regeneration from alkali burns in mini-pigs.
Simpson F, McTiernan C, Islam M, Buznyk O, Lewis P, Meek K
Commun Biol. 2021; 4(1):608.
PMID: 34021240
PMC: 8140136.
DOI: 10.1038/s42003-021-02108-y.
Corneal Biomechanical Assessment with Ultra-High-Speed Scheimpflug Imaging During Non-Contact Tonometry: A Prospective Review.
Baptista P, Ambrosio R, Oliveira L, Meneres P, Beirao J
Clin Ophthalmol. 2021; 15:1409-1423.
PMID: 33854295
PMC: 8039844.
DOI: 10.2147/OPTH.S301179.
Optical Coherence Tomography Guided Robotic Needle Insertion for Deep Anterior Lamellar Keratoplasty.
Draelos M, Tang G, Keller B, Kuo A, Hauser K, Izatt J
IEEE Trans Biomed Eng. 2019; 67(7):2073-2083.
PMID: 31751219
PMC: 7365552.
DOI: 10.1109/TBME.2019.2954505.
Finite element analysis of cornea deformation and curvature change during the keratoplasty suturing process.
Baek J, Park S
Biomed Eng Lett. 2019; 9(2):203-209.
PMID: 31168425
PMC: 6520425.
DOI: 10.1007/s13534-019-00100-4.
The influence of hydration on different mechanical moduli of the cornea.
Seiler T, Shao P, Frueh B, Yun S, Seiler T
Graefes Arch Clin Exp Ophthalmol. 2018; 256(9):1653-1660.
PMID: 30043266
DOI: 10.1007/s00417-018-4069-7.
Transient viscous response of the human cornea probed with the Surface Force Apparatus.
Zappone B, Patil N, Lombardo M, Lombardo G
PLoS One. 2018; 13(5):e0197779.
PMID: 29799859
PMC: 5969749.
DOI: 10.1371/journal.pone.0197779.
Thae use of microfluic spinning fiber as an ophthalmology suture showing the good anastomotic strength control.
Park D, Yong I, Cho K, Cheng J, Jung Y, Kim S
Sci Rep. 2017; 7(1):16264.
PMID: 29176617
PMC: 5701120.
DOI: 10.1038/s41598-017-16462-7.
The hierarchical response of human corneal collagen to load.
Bell J, Hayes S, Whitford C, Sanchez-Weatherby J, Shebanova O, Vergari C
Acta Biomater. 2017; 65:216-225.
PMID: 29128531
PMC: 5729024.
DOI: 10.1016/j.actbio.2017.11.015.
Material Properties of Human Ocular Tissue at 7-µm Resolution.
Rohrbach D, Ito K, Lloyd H, Silverman R, Yoshida K, Yamaguchi T
Ultrason Imaging. 2017; 39(5):313-325.
PMID: 28675987
PMC: 7536713.
DOI: 10.1177/0161734617713498.
Plastic modification of the cornea by pneumatic force corrects myopia: Pneumatic keratology.
Medina A
Eye (Lond). 2017; 31(11):1621-1627.
PMID: 28622329
PMC: 5684457.
DOI: 10.1038/eye.2017.123.
Biomechanical Diagnostics of the Cornea.
De Stefano V, Dupps Jr W
Int Ophthalmol Clin. 2017; 57(3):75-86.
PMID: 28590282
PMC: 5463580.
DOI: 10.1097/IIO.0000000000000172.
Nanotechnology-based strategies for treatment of ocular disease.
Weng Y, Liu J, Jin S, Guo W, Liang X, Hu Z
Acta Pharm Sin B. 2017; 7(3):281-291.
PMID: 28540165
PMC: 5430571.
DOI: 10.1016/j.apsb.2016.09.001.
Biomechanical Measurement of Rabbit Cornea by a Modified Scheimpflug Device.
Zhang B, Gu J, Zhang X, Yang B, Wang Z, Zheng D
J Ophthalmol. 2016; 2016:8271762.
PMID: 27446608
PMC: 4947499.
DOI: 10.1155/2016/8271762.
Measurement of an Elasticity Map in the Human Cornea.
Mikula E, Jester J, Juhasz T
Invest Ophthalmol Vis Sci. 2016; 57(7):3282-6.
PMID: 27327584
PMC: 4961063.
DOI: 10.1167/iovs.15-18248.
High intercorneal symmetry in corneal biomechanical metrics.
Zheng X, Bao F, Geraghty B, Huang J, Yu A, Wang Q
Eye Vis (Lond). 2016; 3:7.
PMID: 26949709
PMC: 4779259.
DOI: 10.1186/s40662-016-0037-7.