» Articles » PMID: 37760118

The Development of a Permanent Implantable Spacer with the Function of Size Adjustability for Customized Treatment of Regurgitant Heart Valve Disease

Overview
Date 2023 Sep 28
PMID 37760118
Authors
Affiliations
Soon will be listed here.
Abstract

The Pivot Mandu is an innovative device featuring a leak-tight adjustable 3D balloon spacer, incorporating inner mesh support, an outer e-PTFE layer, and a compliant balloon in the middle layer with a specialized detachable system. To assess its feasibility, proof of concept was rigorously evaluated through bench testing and survival porcine animal experiments. The results demonstrated successful remote inflation of the balloon system, with the balloon spacer exhibiting sustained patent and functional integrity over an extended observation period of up to 6 months. A noteworthy feature of the newly designed 3D balloon spacer is its capability for easy size adjustment during procedures, enhancing its adaptability and practicality in clinical settings. This three-layered 3D balloon spacer, with its established long-term patency, exhibits highly encouraging outcomes that hold promise in overcoming the current limitations of spacer devices for heart valve diseases. Given the compelling results from preclinical investigations, the translation of the Pivot Mandu into human trials is strongly warranted.

References
1.
Asmarats L, Perlman G, Praz F, Hensey M, Chrissoheris M, Philippon F . Long-Term Outcomes of the FORMA Transcatheter Tricuspid Valve Repair System for the Treatment of Severe Tricuspid Regurgitation: Insights From the First-in-Human Experience. JACC Cardiovasc Interv. 2019; 12(15):1438-1447. DOI: 10.1016/j.jcin.2019.04.038. View

2.
Ali M, Busfield J, Rehman I . Auxetic oesophageal stents: structure and mechanical properties. J Mater Sci Mater Med. 2013; 25(2):527-53. DOI: 10.1007/s10856-013-5067-2. View

3.
Soldani G, Losi P, Bernabei M, Burchielli S, Chiappino D, Kull S . Long term performance of small-diameter vascular grafts made of a poly(ether)urethane-polydimethylsiloxane semi-interpenetrating polymeric network. Biomaterials. 2009; 31(9):2592-605. DOI: 10.1016/j.biomaterials.2009.12.017. View

4.
Kim S, Liu S . Smart and Biostable Polyurethanes for Long-Term Implants. ACS Biomater Sci Eng. 2021; 4(5):1479-1490. DOI: 10.1021/acsbiomaterials.8b00301. View

5.
Kim J, Sung S, Chon M, Kim J, Lee S, Lee S . Mitral loop cerclage as a variant form of mitral cerclage annuloplasty that adds a device (CSTV) for preventing potential complications: a preclinical proof of concept and feasibility study. EuroIntervention. 2016; 11(14):e1669-79. DOI: 10.4244/EIJV11I14A319. View