» Articles » PMID: 37753110

Labral Reconstruction Via Capsular Augmentation Maintains Perfusion to the Acetabular Labrum and Locally Transferred Autograft: An in Vivo Laser Doppler Flowmetry Analysis

Overview
Date 2023 Sep 27
PMID 37753110
Authors
Affiliations
Soon will be listed here.
Abstract

Background: The purpose of the present study was to examine the effects of arthroscopic labral repair with capsular augmentation on blood flow in vivo with use of laser Doppler flowmetry (LDF) to measure microvascular perfusion of the labrum and autograft tissue.

Methods: The present prospective case series included patients ≥18 years old who underwent arthroscopic acetabular labral repair with capsular augmentation; all procedures were performed by a single surgeon between 2018 and 2022. The LDF probe measured microvascular blood flow flux within 1 mm of the surrounding labral and capsular tissue of interest. Mean baseline measurements of flux were compared with readings immediately following capsular elevation and after completing labral augmentation. Blood flux changes were expressed as the percent change from the baseline measurements.

Results: The present study included 41 patients (24 men [58.5%] and 17 women [41.5%]) with a mean age (and standard deviation) of 31.3 ± 8.4 years, a mean BMI of 24.6 ± 3.4 kg/m, a mean lateral center-edge of angle 35.3° ± 4.9°, a mean Tönnis angle of 5.8° ± 5.8°, and a mean arterial pressure of 93.7 ± 10.9 mm Hg. Following capsular elevation, the mean percent change in capsular blood flow flux was significantly different from baseline (-9.24% [95% confidence interval (CI), -18.1% to -0.04%]; p < 0.001). Following labral augmentation, the mean percent change in labral blood flow flux was significantly different from baseline both medially (-22.3% [95% CI, -32.7% to -11.9%]; p < 0.001) and laterally (-32.5% [95% CI, -41.5% to -23.6%]; p = 0.041). There was no significant difference between the changes in medial and lateral perfusion following repair (p = 0.136).

Conclusions: Labral repair with capsular augmentation sustains a reduced blood flow to the native labrum and capsular tissue at the time of fixation. The biological importance of this reduction is unknown, but these findings may serve as a benchmark for other labral preservation techniques and support future correlations with clinical outcomes.

Level Of Evidence: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

Citing Articles

Advances in Molecular Research on Hip Joint Impingement-A Vascular Perspective.

Huzum R, Hinganu M, Huzum B, Hinganu D Biomolecules. 2024; 14(7).

PMID: 39062498 PMC: 11275018. DOI: 10.3390/biom14070784.


Association Between Chondrolabral Junction Breakdown and Conversion to Total Hip Arthroplasty After Hip Arthroscopy for Symptomatic Labral Tears: Minimum 8-Year Follow-up.

Dean M, Cherian N, LaPorte Z, Eberlin C, Wang C, Torabian K Am J Sports Med. 2024; 52(5):1153-1164.

PMID: 38476016 PMC: 10986152. DOI: 10.1177/03635465241234258.

References
1.
Minokawa S, Naito M, Kinoshita K, Yamamoto T . Acetabular labrum blood flow in developmental dysplasia of the hip: an intraoperative in vivo study using laser Doppler flowmetry. J Orthop Surg Res. 2016; 11(1):116. PMC: 5067908. DOI: 10.1186/s13018-016-0450-6. View

2.
Espinosa N, Rothenfluh D, Beck M, Ganz R, Leunig M . Treatment of femoro-acetabular impingement: preliminary results of labral refixation. J Bone Joint Surg Am. 2006; 88(5):925-35. DOI: 10.2106/JBJS.E.00290. View

3.
Kucharik M, Abraham P, Nazal M, Varady N, Eberlin C, Meek W . Arthroscopic Acetabular Labral Repair Versus Labral Debridement: Long-term Survivorship and Functional Outcomes. Orthop J Sports Med. 2022; 10(7):23259671221109012. PMC: 9274418. DOI: 10.1177/23259671221109012. View

4.
Shi Y, Chen L, Xu Y, Hu X, Ao Y, Wang J . Acetabular Labral Reconstruction With Autologous Tendon Tissue in a Porcine Model: In Vivo Histological Assessment and Gene Expression Analysis of the Healing Tissue. Am J Sports Med. 2016; 44(4):1031-9. DOI: 10.1177/0363546515623784. View

5.
Swiontkowski M, Schlehr F, Sanders R, Limbird T, Pou A, Collins J . Direct, real time measurement of meniscal blood flow. An experimental investigation in sheep. Am J Sports Med. 1988; 16(5):429-33. DOI: 10.1177/036354658801600501. View