» Articles » PMID: 37752365

Lung Aeration Estimated by Chest Electrical Impedance Tomography and Lung Ultrasound During Extubation

Overview
Specialty Critical Care
Date 2023 Sep 26
PMID 37752365
Authors
Affiliations
Soon will be listed here.
Abstract

Background: This study hypothesized that patients with extubation failure exhibit a loss of lung aeration and heterogeneity in air distribution, which could be monitored by chest EIT and lung ultrasound. Patients at risk of extubation failure were included after a successful spontaneous breathing trial. Lung ultrasound [with calculation of lung ultrasound score (LUS)] and chest EIT [with calculation of the global inhomogeneity index, frontback center of ventilation (CoV), regional ventilation delay (RVD) and surface available for ventilation] were performed before extubation during pressure support ventilation (H0) and two hours after extubation during spontaneous breathing (H2). EIT was then repeated 6 h (H6) after extubation. EIT derived indices and LUS were compared between patients successfully extubated and patients with extubation failure.

Results: 40 patients were included, of whom 12 (30%) failed extubation. Before extubation, when compared with patients with successful extubation, patients who failed extubation had a higher LUS (19 vs 10, p = 0.003) and a smaller surface available for ventilation (352 vs 406 pixels, p = 0.042). After extubation, GI index and LUS were higher in the extubation failure group, whereas the surface available for ventilation was lower. The RVD and the CoV were not different between groups.

Conclusion: Before extubation, a loss of lung aeration was observed in patients who developed extubation failure afterwards. After extubation, this loss of lung aeration persisted and was associated with regional lung ventilation heterogeneity. Trial registration Clinical trials, NCT04180410, Registered 27 November 2019-prospectively registered, https://clinicaltrials.gov/ct2/show/NCT04180410 .

Citing Articles

Ventilation distribution during spontaneous breathing trials predicts liberation from mechanical ventilation: the VISION study.

Phoophiboon V, Rodrigues A, Vieira F, Ko M, Madotto F, Schreiber A Crit Care. 2025; 29(1):11.

PMID: 39773268 PMC: 11705700. DOI: 10.1186/s13054-024-05243-0.


Electrical impedance tomography monitoring in adult ICU patients: state-of-the-art, recommendations for standardized acquisition, processing, and clinical use, and future directions.

Scaramuzzo G, Pavlovsky B, Adler A, Baccinelli W, Bodor D, Damiani L Crit Care. 2024; 28(1):377.

PMID: 39563476 PMC: 11577873. DOI: 10.1186/s13054-024-05173-x.


Electrical Impedance Tomography as a monitoring tool during weaning from mechanical ventilation: an observational study during the spontaneous breathing trial.

Wisse J, Goos T, Jonkman A, Somhorst P, Reiss I, Endeman H Respir Res. 2024; 25(1):179.

PMID: 38664685 PMC: 11044327. DOI: 10.1186/s12931-024-02801-6.

References
1.
Frerichs I, Amato M, van Kaam A, Tingay D, Zhao Z, Grychtol B . Chest electrical impedance tomography examination, data analysis, terminology, clinical use and recommendations: consensus statement of the TRanslational EIT developmeNt stuDy group. Thorax. 2016; 72(1):83-93. PMC: 5329047. DOI: 10.1136/thoraxjnl-2016-208357. View

2.
Ferre A, Guillot M, Lichtenstein D, Meziere G, Richard C, Teboul J . Lung ultrasound allows the diagnosis of weaning-induced pulmonary oedema. Intensive Care Med. 2019; 45(5):601-608. DOI: 10.1007/s00134-019-05573-6. View

3.
Dres M, Rozenberg E, Morawiec E, Mayaux J, Delemazure J, Similowski T . Diaphragm dysfunction, lung aeration loss and weaning-induced pulmonary oedema in difficult-to-wean patients. Ann Intensive Care. 2021; 11(1):99. PMC: 8237539. DOI: 10.1186/s13613-021-00886-6. View

4.
Epstein S, Ciubotaru R . Independent effects of etiology of failure and time to reintubation on outcome for patients failing extubation. Am J Respir Crit Care Med. 1998; 158(2):489-93. DOI: 10.1164/ajrccm.158.2.9711045. View

5.
Longhini F, Maugeri J, Andreoni C, Ronco C, Bruni A, Garofalo E . Electrical impedance tomography during spontaneous breathing trials and after extubation in critically ill patients at high risk for extubation failure: a multicenter observational study. Ann Intensive Care. 2019; 9(1):88. PMC: 6692788. DOI: 10.1186/s13613-019-0565-0. View