» Articles » PMID: 37740771

Comparison Among Three Lung Ultrasound Scores Used to Predict the Need for Surfactant Replacement Therapy: a Retrospective Diagnostic Accuracy Study in a Cohort of Preterm Infants

Abstract

Lung ultrasound (LU) has emerged as the imaging technique of choice for the assessment of neonates with respiratory distress syndrome (RDS) at the bedside. Scoring systems were developed to quantify RDS severity and to predict the need for surfactant administration. There is no data on the comparison of the three main LU scores (LUS) proposed by Brat, Raimondi and Rodriguez-Fanjul. Moreover, there is not enough evidence to recommend which score and which cut-off has the best ability to predict surfactant need. The three LUS were compared in terms of ability to predict the need for surfactant and reproducibility in a cohort of very preterm infants. This was an observational, retrospective, multicenter study. Neonates below 32 weeks of gestational age with RDS, on non-invasive ventilation with a LU performed prior to surfactant administration (1-3 h of life) were included. Brat, Raimondi, and Rodriguez-Fanjul's scores were calculated for each patient. Receiver-operating characteristic (ROC) curve analysis was used to assess the ability to predict surfactant administration. K-Cohen test, Bland-Altman, and intraclass correlation coefficients were used to assess the intra and interobserver variability. Fifty-four preterm infants were enrolled. Brat, Raimondi, and Rodriguez-Fanjul scores showed a strong ability to predict the need for surfactant: the AUCs were 0.85 (95% CI 0.74-0.96), 0.85 (95% CI 0.75-0.96), and 0.79 (95% CI 0.67-0.92), respectively. No significant differences have been found between the AUCs using the DeLong test. Brat and Raimondi's scores had an optimal cut-off value > 8, while the Rodriguez-Fanjul's score > 10. The k-Cohen values of intraobserver agreement for Brat, Raimondi, and Rodriguez-Fanjul's scores were 0.896 (0.698-1.000), 1.000 (1.000-1.000), and 0.922 (0.767-1.000), respectively. The k-Cohen values of interobserver agreement were 0.896 (0.698-1.000), 0.911 (0.741-1.000), and 0.833 (0.612-1.000), respectively.Conclusions: The three LUS had an excellent ability to predict the need for surfactant and an optimal intra and interobserver agreement. The differences found between the three scores are minimal with negligible clinical implications. Since the optimal cut-off value differed, the same score should be used consistently within the same center. What is Known: • Lung ultrasound is a useful bedside imaging tool that should be used in the assessment of neonates with RDS • Scoring systems or lung ultrasound scores allow to quantify the severity of the pulmonary disease and to predict the need for surfactant replacement therapy What is New: • The three lung ultrasound scores by Brat, Raimondi and Rodriguez-Fanjul have an excellent ability to predict the need for surfactant replacement therapy, although with different cut-off values • All three lung ultrasound scores had an excellent intra and interobserver reproducibility.

Citing Articles

Lung Ultrasound in Neonatal Respiratory Distress Syndrome: A Narrative Review of the Last 10 Years.

Costa F, Titolo A, Ferrocino M, Biagi E, DellOrto V, Perrone S Diagnostics (Basel). 2025; 14(24.

PMID: 39767155 PMC: 11674376. DOI: 10.3390/diagnostics14242793.


Clinical predictors for surfactant retreatment in preterm infants with respiratory distress syndrome: the results of a pooled analysis.

Dani C, Poggi C, Agosti M, Bellettato M, Betta P, Biban P Ital J Pediatr. 2025; 51(1):1.

PMID: 39757182 PMC: 11702167. DOI: 10.1186/s13052-024-01828-1.


Quantitative Lung Ultrasound and Pediatric Critical Care: Any Excuse Not to Use It?.

Mongodi S, De Luca D Am J Respir Crit Care Med. 2024; .

PMID: 39556412 PMC: 11755367. DOI: 10.1164/rccm.202411-2144ED.


Proportion of confluent B-Lines predicts respiratory support in term infants shortly after birth.

Lin X, Zhang H, Wang X, Zhang R, Zhang L, You X Respir Res. 2024; 25(1):307.

PMID: 39138486 PMC: 11323528. DOI: 10.1186/s12931-024-02944-6.


Lung Ultrasound Score in Neonatal RDS: Agreement between Sonography Expert and Neonatologists with Varying Levels of Experience.

Puskarz-Gasowska J, Kruczek P, Hozejowski R, Stefanska M, Blaz W, Sadowska-Krawczenko I Healthcare (Basel). 2024; 12(14).

PMID: 39057594 PMC: 11276990. DOI: 10.3390/healthcare12141450.


References
1.
Singh Y, Tissot C, Fraga M, Yousef N, Cortes R, Lopez J . International evidence-based guidelines on Point of Care Ultrasound (POCUS) for critically ill neonates and children issued by the POCUS Working Group of the European Society of Paediatric and Neonatal Intensive Care (ESPNIC). Crit Care. 2020; 24(1):65. PMC: 7041196. DOI: 10.1186/s13054-020-2787-9. View

2.
Lichtenstein D, Menu Y . A bedside ultrasound sign ruling out pneumothorax in the critically ill. Lung sliding. Chest. 1995; 108(5):1345-8. DOI: 10.1378/chest.108.5.1345. View

3.
Corsini I, Parri N, Ficial B, Dani C . Lung ultrasound in the neonatal intensive care unit: Review of the literature and future perspectives. Pediatr Pulmonol. 2020; 55(7):1550-1562. DOI: 10.1002/ppul.24792. View

4.
Nguyen J . Call for point-of-care ultrasound training regimens in neonatal-perinatal medicine. J Pediatr. 2017; 185:254. DOI: 10.1016/j.jpeds.2017.02.029. View

5.
Perri A, Riccardi R, Iannotta R, Di Molfetta D, Arena R, Vento G . Lung ultrasonography score versus chest X-ray score to predict surfactant administration in newborns with respiratory distress syndrome. Pediatr Pulmonol. 2018; 53(9):1231-1236. DOI: 10.1002/ppul.24076. View