Abstract

Purpose: Force plates can be used to monitor landing asymmetries during rehabilitation, but they are not widely available. Accelerometer-based wearable technology may be a more feasible solution. The purpose of this article was to determine the agreement between impact accelerations measured with force plates and accelerometer-derived measures of (1) centre of mass (COM) acceleration and (2) tibial acceleration asymmetries during bilateral landings.

Method: Participants completed three countermovement jumps (CMJ) and three squat jumps (SJ) on dual force plates with triaxial accelerometers attached to each tibia and lower back, near the COM. Bland and Altman 95% limits of agreement (95% LOA) were calculated.

Results: 19 adults ( = 11; 58% women, = 8; 42% men) participated in the study. The mean differences between impact and COM accelerations were 0.24 g (95% LOA: -1.34 g to 1.82 g) and 0.38 g (95% LOA: -1.15 to 1.91 g) for the CMJ and SJ, respectively. The mean differences between the impact and tibial acceleration-based lower limb asymmetries in the CMJ and SJ were -6% (95% LOA: -32% to 19%) and 0% (95% LOA: -45% to 45%), respectively.

Conclusions: Our findings show acceptable agreement between impact acceleration and accelerometer-based COM acceleration and lack of agreement between impact accelerations and accelerometer-based tibial acceleration asymmetries. COM acceleration could be used to quantify landing impacts during rehabilitation, but we do not consider the accelerometer-based asymmetry measures to be a suitable alternative for force plate-based measures. Future work should focus on determining normative values for lower extremity asymmetries during landing tasks.

References
1.
Benson L, Tait T, Befus K, Choi J, Hillson C, Stilling C . Validation of a commercially available inertial measurement unit for recording jump load in youth basketball players. J Sports Sci. 2020; 38(8):928-936. DOI: 10.1080/02640414.2020.1737360. View

2.
Paterno M, Ford K, Myer G, Heyl R, Hewett T . Limb asymmetries in landing and jumping 2 years following anterior cruciate ligament reconstruction. Clin J Sport Med. 2007; 17(4):258-62. DOI: 10.1097/JSM.0b013e31804c77ea. View

3.
Pouliot-Laforte A, Veilleux L, Rauch F, Lemay M . Validity of an accelerometer as a vertical ground reaction force measuring device in healthy children and adolescents and in children and adolescents with osteogenesis imperfecta type I. J Musculoskelet Neuronal Interact. 2014; 14(2):155-61. View

4.
Elvin N, Elvin A, Arnoczky S . Correlation between ground reaction force and tibial acceleration in vertical jumping. J Appl Biomech. 2007; 23(3):180-9. DOI: 10.1123/jab.23.3.180. View

5.
Myer G, Paterno M, Ford K, Quatman C, Hewett T . Rehabilitation after anterior cruciate ligament reconstruction: criteria-based progression through the return-to-sport phase. J Orthop Sports Phys Ther. 2006; 36(6):385-402. DOI: 10.2519/jospt.2006.2222. View