Abstract

With the incidence of primary total hip arthroplasty continuing to rise in the United States, the innovation behind improving current total hip arthroplasty systems inevitably grows with it-each new design potentially ushering in new flaws. We report a case of screw failure with the Arcos Modular Femoral Revision System-Trochanteric Bolt and Claw Technique in a 74-year-old male patient. The patient presented to the investigator's clinic for their 20-month follow-up evaluation of their complex right hip revision. Radiographs revealed failure of the screw attaching the claw plate to the stem resulting in dislodgement and relocation of the screw within the intra-articular cavity. The patient elected for nonsurgical management and will continue to be monitored. Consent by the patient involved in this case report was obtained.

Citing Articles

Clinical outcomes and survival rates of a uncemented modular revision stem system in hip arthroplasty: a 10-year single-institution study on a frail population.

De Meo D, Martini P, Perciballi B, Guarascio G, Vacca M, Cera G Arch Orthop Trauma Surg. 2024; 144(8):3833-3840.

PMID: 39126455 PMC: 11417061. DOI: 10.1007/s00402-024-05483-3.

References
1.
Bozic K, Kamath A, Ong K, Lau E, Kurtz S, Chan V . Comparative Epidemiology of Revision Arthroplasty: Failed THA Poses Greater Clinical and Economic Burdens Than Failed TKA. Clin Orthop Relat Res. 2014; 473(6):2131-8. PMC: 4418985. DOI: 10.1007/s11999-014-4078-8. View

2.
Bonnevialle P, Saragaglia D, Ehlinger M, Tonetti J, Maisse N, Adam P . Trochanteric locking nail versus arthroplasty in unstable intertrochanteric fracture in patients aged over 75 years. Orthop Traumatol Surg Res. 2011; 97(6 Suppl):S95-100. DOI: 10.1016/j.otsr.2011.06.009. View

3.
Ricciardi B, Nodzo S, Oi K, Lee Y, Westrich G . Radiographic outcomes of cable-plate versus cable-grip fixation in periprosthetic fractures of the proximal femur. Hip Int. 2017; 27(6):584-588. DOI: 10.5301/hipint.5000496. View

4.
Hoffmann M, Lotzien S, Schildhauer T . Clinical outcome of interprosthetic femoral fractures treated with polyaxial locking plates. Injury. 2016; 47(4):934-8. DOI: 10.1016/j.injury.2015.12.026. View

5.
Hendel D, Yasin M, Garti A, Weisbort M, Beloosesky Y . Fracture of the greater trochanter during hip replacement: a retrospective analysis of 21/372 cases. Acta Orthop Scand. 2002; 73(3):295-7. DOI: 10.1080/000164702320155284 . View