Abstract

The environmental impact of magnetic resonance imaging (MRI) has recently come into focus. This includes its enormous demand for electricity compared to other imaging modalities and contamination of water bodies with anthropogenic gadolinium related to contrast administration. Given the pressing threat of climate change, addressing these challenges to improve the environmental sustainability of MRI is imperative. The purpose of this review is to discuss the challenges, opportunities, and the need for action to reduce the environmental impact of MRI and prepare for the effects of climate change. The approaches outlined are categorized as strategies to reduce greenhouse gas (GHG) emissions from MRI during production and use phases, approaches to reduce the environmental impact of MRI including the preservation of finite resources, and development of adaption plans to prepare for the impact of climate change. Co-benefits of these strategies are emphasized including lower GHG emission and reduced cost along with improved heath and patient satisfaction. Although MRI is energy-intensive, there are many steps that can be taken now to improve the environmental sustainability of MRI and prepare for the effects of climate change. On-going research, technical development, and collaboration with industry partners are needed to achieve further reductions in MRI-related GHG emissions and to decrease the reliance on finite resources. LEVEL OF EVIDENCE: 5 TECHNICAL EFFICACY: Stage 6.

Citing Articles

Gadolinium-Based Contrast Agents (GBCAs) for MRI: A Benefit-Risk Balance Analysis from a Chemical, Biomedical, and Environmental Point of View.

Scarciglia A, Papi C, Romiti C, Leone A, Di Gregorio E, Ferrauto G Glob Chall. 2025; 9(3):2400269.

PMID: 40071223 PMC: 11891575. DOI: 10.1002/gch2.202400269.


Nanophotonic-enhanced photoacoustic imaging for brain tumor detection.

Rizwan A, Sridharan B, Park J, Kim D, Vial J, Kyhm K J Nanobiotechnology. 2025; 23(1):170.

PMID: 40045308 PMC: 11881315. DOI: 10.1186/s12951-025-03204-5.


Sustainability in radiology: position paper and call to action from ACR, AOSR, ASR, CAR, CIR, ESR, ESRNM, ISR, IS3R, RANZCR, and RSNA.

Rockall A, Allen B, Brown M, El-Diasty T, Fletcher J, Gerson R Eur Radiol. 2025; .

PMID: 40009087 DOI: 10.1007/s00330-025-11413-7.


Environmental Sustainability in the Outpatient Clinic Setting.

Sattler M, Abdelnour M, McKay V, Burnham J Open Forum Infect Dis. 2025; 12(2):ofae586.

PMID: 39958525 PMC: 11825988. DOI: 10.1093/ofid/ofae586.


Use of AI in Cardiac CT and MRI: A Scientific Statement from the ESCR, EuSoMII, NASCI, SCCT, SCMR, SIIM, and RSNA.

Mastrodicasa D, van Assen M, Huisman M, Leiner T, Williamson E, Nicol E Radiology. 2025; 314(1):e240516.

PMID: 39873607 PMC: 11783164. DOI: 10.1148/radiol.240516.


References
1.
Heiss R, Nagel A, Laun F, Uder M, Bickelhaupt S . Low-Field Magnetic Resonance Imaging: A New Generation of Breakthrough Technology in Clinical Imaging. Invest Radiol. 2021; 56(11):726-733. DOI: 10.1097/RLI.0000000000000805. View

2.
Romanello M, Di Napoli C, Drummond P, Green C, Kennard H, Lampard P . The 2022 report of the Lancet Countdown on health and climate change: health at the mercy of fossil fuels. Lancet. 2022; 400(10363):1619-1654. PMC: 7616806. DOI: 10.1016/S0140-6736(22)01540-9. View

3.
Rudie J, Gleason T, Barkovich M, Wilson D, Shankaranarayanan A, Zhang T . Clinical Assessment of Deep Learning-based Super-Resolution for 3D Volumetric Brain MRI. Radiol Artif Intell. 2022; 4(2):e210059. PMC: 8980882. DOI: 10.1148/ryai.210059. View

4.
Sumner C, Ikuta I, Garg T, Martin J, Mansoori B, Chalian M . Approaches to Greening Radiology. Acad Radiol. 2022; 30(3):528-535. DOI: 10.1016/j.acra.2022.08.013. View

5.
Inoue K, Fukushi M, Furukawa A, Sahoo S, Veerasamy N, Ichimura K . Impact on gadolinium anomaly in river waters in Tokyo related to the increased number of MRI devices in use. Mar Pollut Bull. 2020; 154:111148. DOI: 10.1016/j.marpolbul.2020.111148. View