» Articles » PMID: 37631816

Dispersion Turning Attenuation Microfiber for Flowrate Sensing

Overview
Journal Sensors (Basel)
Publisher MDPI
Specialty Biotechnology
Date 2023 Aug 26
PMID 37631816
Authors
Affiliations
Soon will be listed here.
Abstract

We demonstrated a new optical fiber modal interferometer (MI) for airflow sensing; the novelty of the proposed structure is that an MI is fabricated based on a piece of HAF, which makes the sensitive MI itself also a hotwire. The interferometer is made by applying arc-discharge tapering and then flame tapering on a 10 mm length high attenuation fiber (HAF, 2 dB/cm) with both ends spliced to a normal single mode fiber. When the diameter of the fiber in the processing region is reduced to about 2 μm, the near-infrared dispersion turning point (DTP) can be observed in the interferometer's transmission spectrum. Due to the absorption of the HAF, the interferometer will have a large temperature increase under the action of a pump laser. At the same time, the spectrum of the interferometer with a DTP is very sensitive to the change in ambient temperature. Since airflow will significantly affect the temperature around the fiber, this thermosensitive interferometer with an integrated heat source is suitable for airflow sensing. Such an airflow sensor sample with a 31.2 mm length was made and pumped by a 980 nm laser with power up to 200 mW. In the comparative experiment with an electrical anemometer, this sensor exhibits a very high air-flow sensitivity of -2.69 nm/(m/s) at a flowrate of about 1.0 m/s. The sensitivity can be further improved by enlarging the waist length, increasing the pump power, etc. The optical anemometer with an extremely high sensitivity and a compact size has the potential to measure a low flowrate in constrained microfluidic channels.

References
1.
Uddin N, Liu G, Sheng Q, Han M . Constant temperature operation of fiber-optic hot-wire anemometers. Opt Lett. 2019; 44(10):2578-2581. DOI: 10.1364/OL.44.002578. View

2.
Gao R, Lu D . Temperature compensated fiber optic anemometer based on graphene-coated elliptical core micro-fiber Bragg grating. Opt Express. 2019; 27(23):34011-34021. DOI: 10.1364/OE.27.034011. View

3.
Wang C, Zhang X, Jiang J, Liu K, Wang S, Wang R . Fiber optical temperature compensated anemometer based on dual Fabry-Perot sensors with sealed cavity. Opt Express. 2019; 27(13):18157-18168. DOI: 10.1364/OE.27.018157. View

4.
Njegovec M, Pevec S, donlagic D . Optical Micro-Wire Flow-Velocity Sensor. Sensors (Basel). 2021; 21(12). PMC: 8230618. DOI: 10.3390/s21124025. View

5.
Li H, Zhang J, Yan Z, Lyu G . Fiber-optic airflow velocity sensing method based on a 45° tilt fiber grating combined with a single-walled carbon nanotube coated fiber. Opt Express. 2021; 29(24):40015-40023. DOI: 10.1364/OE.441255. View