» Articles » PMID: 37487685

Diagnostic Accuracy of Different ECG-based Algorithms in Wide QRS Complex Tachycardia: a Systematic Review and Meta-analysis

Overview
Journal BMJ Open
Specialty General Medicine
Date 2023 Jul 24
PMID 37487685
Authors
Affiliations
Soon will be listed here.
Abstract

Objective: Several ECG-based algorithms have been proposed to enhance the effectiveness of distinguishing Wide QRS complex tachycardia (WCT), but a comprehensive comparison of their accuracy is still lacking. This meta-analysis aimed to assess the diagnostic precision of various non-artificial intelligence ECG-based algorithms for WCT.

Design: Systematic review with meta-analysis.

Data Sources: Electronic databases (PubMed, MEDLINE, the Cochrane Library, and Web of Science) are searched up to May 2022.

Eligibility Criteria For Selecting Studies: All studies reporting the diagnostic accuracy of different ECG-based algorithms for WCT are included. The risk of bias in included studies is assessed using the Cochrane Collaboration's risk of bias tools.

Data Extraction And Synthesis: Two independent reviewers extracted data and assessed risk of bias. Data were pooled using random-effects model and expressed as mean differences with 95% CIs. Heterogeneity was calculated by the I method. The Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool was applied to assess the internal validity of the diagnostic studies.

Results: In total, 467 studies were identified, and 14 studies comprising 3966 patients were included, involving four assessable ECG-based algorithms: the Brugada algorithm, Vereckei-pre algorithm, Vereckei-aVR algorithm and R wave peak time of lead II (RWPT-II) algorithm. The overall sensitivity was 88.89% (95% CI: 85.03 to 91.86), with a specificity of 70.55% (95% CI: 62.10 to 77.79) and a diagnostic OR (DOR) of 19.17 (95% CI: 11.45 to 32.10). Heterogeneity of the DOR was 89.1%. The summary sensitivity of each algorithm was Brugada 90.25%, Vereckei-pre 94.80%, Vereckei-aVR 90.35% and RWPT-II 78.15%; the summary specificity was Brugada 64.02%, Vereckei-pre 75.40%, Vereckei-aVR 60.88% and RWPT-II 88.30% and the summary DOR was Brugada 16.48, Vereckei-pre 60.70, Vereckei-aVR 14.57 and RWPT-II 27.00.

Conclusions: ECG-based algorithms exhibit high sensitivity and moderate specificity in diagnosing WCT. A combination of Brugada or Vereckei-aVR algorithm with RWPT-II could be considered to diagnose WCT.

Prospero Registration Number: CRD42022344996.

References
1.
Deeks J, Macaskill P, Irwig L . The performance of tests of publication bias and other sample size effects in systematic reviews of diagnostic test accuracy was assessed. J Clin Epidemiol. 2005; 58(9):882-93. DOI: 10.1016/j.jclinepi.2005.01.016. View

2.
Lin T, Ma Y, Muhu Y, Tang B, Hou Y, Zhang Y . [Value of aVR lead four steps algorithm on differential diagnosis of wide QRS complex tachycardia]. Zhonghua Xin Xue Guan Bing Za Zhi. 2011; 39(1):69-72. View

3.
May A, Brenes-Salazar J, DeSimone C, Vaidya V, Ternus B, Hodge D . Electrocardiogram algorithms used to differentiate wide complex tachycardias demonstrate diagnostic limitations when applied by non-cardiologists. J Electrocardiol. 2018; 51(6):1103-1109. DOI: 10.1016/j.jelectrocard.2018.09.015. View

4.
Lau E, Ng G . Comparison of the performance of three diagnostic algorithms for regular broad complex tachycardia in practical application. Pacing Clin Electrophysiol. 2002; 25(5):822-7. DOI: 10.1046/j.1460-9592.2002.00822.x. View

5.
Akhtar M, Shenasa M, Jazayeri M, Caceres J, Tchou P . Wide QRS complex tachycardia. Reappraisal of a common clinical problem. Ann Intern Med. 1988; 109(11):905-12. DOI: 10.7326/0003-4819-109-11-905. View