» Articles » PMID: 37456517

High-Speed Time-Domain Diffuse Optical Tomography with a Sensitivity Equation-based Neural Network

Overview
Publisher IEEE
Date 2023 Jul 17
PMID 37456517
Authors
Affiliations
Soon will be listed here.
Abstract

Steady progress in time-domain diffuse optical tomography (TD-DOT) technology is allowing for the first time the design of low-cost, compact, and high-performance systems, thus promising more widespread clinical TD-DOT use, such as for recording brain tissue hemodynamics. TD-DOT is known to provide more accurate values of optical properties and physiological parameters compared to its frequency-domain or steady-state counterparts. However, achieving high temporal resolution is still difficult, as solving the inverse problem is computationally demanding, leading to relatively long reconstruction times. The runtime is further compromised by processes that involve 'nontrivial' empirical tuning of reconstruction parameters, which increases complexity and inefficiency. To address these challenges, we present a new reconstruction algorithm that combines a deep-learning approach with our previously introduced sensitivity-equation-based, non-iterative sparse optical reconstruction (SENSOR) code. The new algorithm (called SENSOR-NET) unfolds the iterations of SENSOR into a deep neural network. In this way, we achieve high-resolution sparse reconstruction using only learned parameters, thus eliminating the need to tune parameters prior to reconstruction empirically. Furthermore, once trained, the reconstruction time is not dependent on the number of sources or wavelengths used. We validate our method with numerical and experimental data and show that accurate reconstructions with 1 mm spatial resolution can be obtained in under 20 milliseconds regardless of the number of sources used in the setup. This opens the door for real-time brain monitoring and other high-speed DOT applications.

Citing Articles

A Novel Technique for Fluorescence Lifetime Tomography.

Nizam N, Pandey V, Erbas I, Smith J, Intes X bioRxiv. 2024; .

PMID: 39345436 PMC: 11430024. DOI: 10.1101/2024.09.19.613888.

References
1.
Joseph D, Huppert T, Franceschini M, Boas D . Diffuse optical tomography system to image brain activation with improved spatial resolution and validation with functional magnetic resonance imaging. Appl Opt. 2006; 45(31):8142-51. DOI: 10.1364/ao.45.008142. View

2.
Eggebrecht A, Elison J, Feczko E, Todorov A, Wolff J, Kandala S . Joint Attention and Brain Functional Connectivity in Infants and Toddlers. Cereb Cortex. 2017; 27(3):1709-1720. PMC: 5452276. DOI: 10.1093/cercor/bhw403. View

3.
Feng J, Deng J, Li Z, Sun Z, Dou H, Jia K . End-to-end Res-Unet based reconstruction algorithm for photoacoustic imaging. Biomed Opt Express. 2020; 11(9):5321-5340. PMC: 7510873. DOI: 10.1364/BOE.396598. View

4.
Lu C, Zhang Y, Biswal B, Zang Y, Peng D, Zhu C . Use of fNIRS to assess resting state functional connectivity. J Neurosci Methods. 2009; 186(2):242-9. DOI: 10.1016/j.jneumeth.2009.11.010. View

5.
Bevilacqua F, Piguet D, Marquet P, Gross J, Tromberg B, Depeursinge C . In vivo local determination of tissue optical properties: applications to human brain. Appl Opt. 2008; 38(22):4939-50. DOI: 10.1364/ao.38.004939. View