» Articles » PMID: 37449922

The Advanced Hybrid Closed Loop Improves Glycemia Risk Index, Continuous Glucose Monitoring Index, and Time in Range in Children with Type 1 Diabetes: Real-World Data from a Single Center Study

Overview
Date 2023 Jul 14
PMID 37449922
Authors
Affiliations
Soon will be listed here.
Abstract

The Glycemia Risk Index (GRI) and Continuous Glucose Monitoring Index (COGI) are newly defined composite metric parameters derived from continuous glucose monitoring (CGM) data. GRI is divided into five separate risk zones (from lowest to highest: A-E). In this study, the effect of the advanced hybrid closed loop (AHCL) system on GRI and COGI in children with type 1 diabetes was evaluated. Forty-five children who had started using the AHCL and whose baseline and sixth-month CGM data were available were analyzed in terms of achievement of CGM consensus goals and changes in GRI scores and zones. The paired -test was used for the analyses. The mean age and duration of diabetes of the participants were 10.95 ± 3.41 and 3.85 ± 2.67 years, respectively. The mean GRI score significantly decreased from 35.66 ± 17.46 at baseline to 22.83 ± 9.08 at 6 months ( < 0.001). Although the proportion of those in the A zone was 20% at baseline, it increased to 42% at 6 months. AHCL also improved COGI from 72.59 ± 12.44 to 82.90 ± 7.72 ( < 0.001). Time in range (TIR) increased significantly from 70.54% to 80.51% ( < 0.001) at 6 months. AHCL provides not only an improvement in TIR but also a significant improvement in both GRI and COGI at 6 months. The incorporation of GRI and COGI alongside TIR may enhance the assessment of the glycemic profile by providing a more comprehensive and in-depth analysis.

Citing Articles

Measurement of serum 1,5-AG provides insights for diabetes management and the anti-viral immune response.

Wei M, Gallo L, Hulme K, Alzaid F, Julla J, Dorey E Cell Mol Life Sci. 2025; 82(1):71.

PMID: 39912911 PMC: 11803061. DOI: 10.1007/s00018-024-05568-7.


Correlation Between the Glycemia Risk Index and Longitudinal Hemoglobin A1c in Children and Young Adults With Type 1 Diabetes.

Panfil K, Redel J, Vandervelden C, Lockee B, Kahkoska A, Tallon E J Diabetes Sci Technol. 2024; 18(4):771-778.

PMID: 38715286 PMC: 11307230. DOI: 10.1177/19322968241247219.


The Glycemia Risk Index Predicts Performance of Diabetes Self-Management Habits in Youth With Type 1 Diabetes Mellitus.

Panfil K, Vandervelden C, Lockee B, Tallon E, Williams D, Lee J J Diabetes Sci Technol. 2024; 18(4):779-786.

PMID: 38708581 PMC: 11307237. DOI: 10.1177/19322968241247215.


Real-World Evidence of Automated Insulin Delivery System Use.

Considine E, Sherr J Diabetes Technol Ther. 2024; 26(S3):53-65.

PMID: 38377315 PMC: 10890954. DOI: 10.1089/dia.2023.0442.


Association between glycemia risk index and arterial stiffness in type 2 diabetes.

Cai L, Shen W, Li J, Wang B, Sun Y, Chen Y J Diabetes Investig. 2024; 15(5):614-622.

PMID: 38251792 PMC: 11060162. DOI: 10.1111/jdi.14153.