Inferior Vena Cava Distensibility from Subcostal and Trans-hepatic Imaging Using Both M-mode or Artificial Intelligence: a Prospective Study on Mechanically Ventilated Patients

Overview
Specialty Critical Care
Date 2023 Jul 9
PMID 37423948
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Variation of inferior vena cava (IVC) is used to predict fluid-responsiveness, but the IVC visualization with standard sagittal approach (SC, subcostal) cannot be always achieved. In such cases, coronal trans-hepatic (TH) window may offer an alternative, but the interchangeability of IVC measurements in SC and TH is not fully established. Furthermore, artificial intelligence (AI) with automated border detection may be of clinical value but it needs validation.

Methods: Prospective observational validation study in mechanically ventilated patients with pressure-controlled mode. Primary outcome was the IVC distensibility (IVC-DI) in SC and TH imaging, with measurements taken both in M-Mode or with AI software. We calculated mean bias, limits of agreement (LoA), and intra-class correlation (ICC) coefficient.

Results: Thirty-three patients were included. Feasibility rate was 87.9% and 81.8% for SC and TH visualization, respectively. Comparing imaging from the same anatomical site acquired with different modalities (M-Mode vs AI), we found the following IVC-DI differences: (1) SC: mean bias - 3.1%, LoA [- 20.1; 13.9], ICC = 0.65; (2) TH: mean bias - 2.0%, LoA [- 19.3; 15.4], ICC = 0.65. When comparing the results obtained from the same modality but from different sites (SC vs TH), IVC-DI differences were: (3) M-Mode: mean bias 1.1%, LoA [- 6.9; 9.1], ICC = 0.54; (4) AI: mean bias 2.0%, LoA [- 25.7; 29.7], ICC = 0.32.

Conclusions: In patients mechanically ventilated, AI software shows good accuracy (modest overestimation) and moderate correlation as compared to M-mode assessment of IVC-DI, both for SC and TH windows. However, precision seems suboptimal with wide LoA. The comparison of M-Mode or AI between different sites yields similar results but with weaker correlation. Trial registration Reference protocol: 53/2022/PO, approved on 21/03/2022.

Citing Articles

Exploring the Utility of Renal Resistive Index in Critical Care: Insights into ARDS and Cardiac Failure.

Cuttone G, Geraci G, La Via L, Sorbello M, Pappalardo F, Carollo C Biomedicines. 2025; 13(2).

PMID: 40002933 PMC: 11853387. DOI: 10.3390/biomedicines13020519.


Goal-directed fluid therapy on the postoperative complications of laparoscopic hepatobiliary or pancreatic surgery: An interventional comparative study.

Koo B, Oh A, Na H, Han J, Kim H PLoS One. 2024; 19(12):e0315205.

PMID: 39693362 PMC: 11654985. DOI: 10.1371/journal.pone.0315205.


The Integration of Radiomics and Artificial Intelligence in Modern Medicine.

Maniaci A, Lavalle S, Gagliano C, Lentini M, Masiello E, Parisi F Life (Basel). 2024; 14(10).

PMID: 39459547 PMC: 11508875. DOI: 10.3390/life14101248.


Inferior vena cava distensibility during pressure support ventilation: a prospective study evaluating interchangeability of subcostal and trans‑hepatic views, with both M‑mode and automatic border tracing.

Zawadka M, Santonocito C, Dezio V, Amelio P, Messina S, Cardia L J Clin Monit Comput. 2024; 38(5):981-990.

PMID: 38819726 PMC: 11427491. DOI: 10.1007/s10877-024-01177-8.


Association of adherence to the enhanced recovery after surgery pathway and outcomes after laparoscopic total gastrectomy.

Hao Y, Zhao Q, Jiang K, Feng X, Ma Y, Zhang J BMC Anesthesiol. 2024; 24(1):110.

PMID: 38519945 PMC: 10958831. DOI: 10.1186/s12871-024-02433-9.


References
1.
Muller L, Bobbia X, Toumi M, Louart G, Molinari N, Ragonnet B . Respiratory variations of inferior vena cava diameter to predict fluid responsiveness in spontaneously breathing patients with acute circulatory failure: need for a cautious use. Crit Care. 2012; 16(5):R188. PMC: 3682290. DOI: 10.1186/cc11672. View

2.
Monnet X, Marik P, Teboul J . Prediction of fluid responsiveness: an update. Ann Intensive Care. 2016; 6(1):111. PMC: 5114218. DOI: 10.1186/s13613-016-0216-7. View

3.
Zhang L, Xu F, Li S, Zheng X, Zheng S, Liu H . Influence of fluid balance on the prognosis of patients with sepsis. BMC Anesthesiol. 2021; 21(1):269. PMC: 8569078. DOI: 10.1186/s12871-021-01489-1. View

4.
Bataille B, de Selle J, Moussot P, Marty P, Silva S, Cocquet P . Machine learning methods to improve bedside fluid responsiveness prediction in severe sepsis or septic shock: an observational study. Br J Anaesth. 2021; 126(4):826-834. DOI: 10.1016/j.bja.2020.11.039. View

5.
Blaivas M, Blaivas L, Tsung J . Deep Learning Pitfall: Impact of Novel Ultrasound Equipment Introduction on Algorithm Performance and the Realities of Domain Adaptation. J Ultrasound Med. 2021; 41(4):855-863. DOI: 10.1002/jum.15765. View