» Articles » PMID: 37364741

Whole-Cerebrum Distortion-free Three-dimensional Pseudo-continuous Arterial Spin Labeling at 7T

Overview
Journal Neuroimage
Specialty Radiology
Date 2023 Jun 26
PMID 37364741
Authors
Affiliations
Soon will be listed here.
Abstract

Fulfilling potentials of ultrahigh field for pseudo-Continuous Arterial Spin Labeling (pCASL) has been hampered by B1/B0 inhomogeneities that affect pCASL labeling, background suppression (BS), and the readout sequence. This study aimed to present a whole-cerebrum distortion-free three-dimensional (3D) pCASL sequence at 7T by optimizing pCASL labeling parameters, BS pulses, and an accelerated Turbo-FLASH (TFL) readout. A new set of pCASL labeling parameters (G = 0.4 mT/m, G = 14.67) was proposed to avoid interferences in bottom slices while achieving robust labeling efficiency (LE). An OPTIM BS pulse was designed based on the range of B1/B0 inhomogeneities at 7T. A 3D TFL readout with 2D-CAIPIRINHA undersampling (R = 2 × 2) and centric ordering was developed, and the number of segments (N) and flip angle (FA) were varied in simulation to achieve the optimal trade-off between SNR and spatial blurring. In-vivo experiments were performed on 19 subjects. The results showed that the new set of labeling parameters effectively achieved whole-cerebrum coverage by eliminating interferences in bottom slices while maintaining a high LE. The OPTIM BS pulse achieved 33.3% higher perfusion signal in gray matter (GM) than the original BS pulse with a cost of 4.8-fold SAR. Incorporating a moderate FA (8) and N (2), whole-cerebrum 3D TFL-pCASL imaging was achieved with a 2 × 2 × 4 mm resolution without distortion and susceptibility artifacts compared to 3D GRASE-pCASL. In addition, 3D TFL-pCASL showed a good to excellent test-retest repeatability and potential of higher resolution (2 mm isotropic). The proposed technique also significantly improved SNR when compared to the same sequence at 3T and simultaneous multislice TFL-pCASL at 7T. By combining a new set of labeling parameters, OPTIM BS pulse, and accelerated 3D TFL readout, we achieved high resolution pCASL at 7T with whole-cerebrum coverage, detailed perfusion and anatomical information without distortion, and sufficient SNR.

Citing Articles

Dynamic B field shimming for improving pseudo-continuous arterial spin labeling at 7 T.

Ji Y, Woods J, Li H, Okell T Magn Reson Med. 2024; 93(4):1674-1689.

PMID: 39642063 PMC: 11782713. DOI: 10.1002/mrm.30387.


Assessing Cerebral Microvascular Volumetric Pulsatility with High-Resolution 4D CBV MRI at 7T.

Guo F, Zhao C, Shou Q, Jin N, Jann K, Shao X medRxiv. 2024; .

PMID: 39281763 PMC: 11398588. DOI: 10.1101/2024.09.04.24313077.


Laminar multi-contrast fMRI at 7T allows differentiation of neuronal excitation and inhibition underlying positive and negative BOLD responses.

Shao X, Guo F, Kim J, Ress D, Zhao C, Shou Q medRxiv. 2024; .

PMID: 39040201 PMC: 11261924. DOI: 10.1101/2024.04.01.24305167.


Whole-cerebrum guanidino and amide CEST mapping at 3 T by a 3D stack-of-spirals gradient echo acquisition.

Wang K, Ju L, Song Y, Blair L, Xie K, Liu C Magn Reson Med. 2024; 92(4):1456-1470.

PMID: 38748853 PMC: 11262991. DOI: 10.1002/mrm.30134.

References
1.
Griswold M, Jakob P, Heidemann R, Nittka M, Jellus V, Wang J . Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn Reson Med. 2002; 47(6):1202-10. DOI: 10.1002/mrm.10171. View

2.
Detre J, Leigh J, Williams D, Koretsky A . Perfusion imaging. Magn Reson Med. 1992; 23(1):37-45. DOI: 10.1002/mrm.1910230106. View

3.
Rund A, Aigner C, Kunisch K, Stollberger R . Simultaneous multislice refocusing via time optimal control. Magn Reson Med. 2018; 80(4):1416-1428. DOI: 10.1002/mrm.27124. View

4.
Bian W, Tranvinh E, Tourdias T, Han M, Liu T, Wang Y . In Vivo 7T MR Quantitative Susceptibility Mapping Reveals Opposite Susceptibility Contrast between Cortical and White Matter Lesions in Multiple Sclerosis. AJNR Am J Neuroradiol. 2016; 37(10):1808-1815. PMC: 5148739. DOI: 10.3174/ajnr.A4830. View

5.
Jang A, Wu X, Auerbach E, Garwood M . Designing 3D selective adiabatic radiofrequency pulses with single and parallel transmission. Magn Reson Med. 2017; 79(2):701-710. PMC: 5682242. DOI: 10.1002/mrm.26720. View