Whole-Cerebrum Distortion-free Three-dimensional Pseudo-continuous Arterial Spin Labeling at 7T
Overview
Authors
Affiliations
Fulfilling potentials of ultrahigh field for pseudo-Continuous Arterial Spin Labeling (pCASL) has been hampered by B1/B0 inhomogeneities that affect pCASL labeling, background suppression (BS), and the readout sequence. This study aimed to present a whole-cerebrum distortion-free three-dimensional (3D) pCASL sequence at 7T by optimizing pCASL labeling parameters, BS pulses, and an accelerated Turbo-FLASH (TFL) readout. A new set of pCASL labeling parameters (G = 0.4 mT/m, G = 14.67) was proposed to avoid interferences in bottom slices while achieving robust labeling efficiency (LE). An OPTIM BS pulse was designed based on the range of B1/B0 inhomogeneities at 7T. A 3D TFL readout with 2D-CAIPIRINHA undersampling (R = 2 × 2) and centric ordering was developed, and the number of segments (N) and flip angle (FA) were varied in simulation to achieve the optimal trade-off between SNR and spatial blurring. In-vivo experiments were performed on 19 subjects. The results showed that the new set of labeling parameters effectively achieved whole-cerebrum coverage by eliminating interferences in bottom slices while maintaining a high LE. The OPTIM BS pulse achieved 33.3% higher perfusion signal in gray matter (GM) than the original BS pulse with a cost of 4.8-fold SAR. Incorporating a moderate FA (8) and N (2), whole-cerebrum 3D TFL-pCASL imaging was achieved with a 2 × 2 × 4 mm resolution without distortion and susceptibility artifacts compared to 3D GRASE-pCASL. In addition, 3D TFL-pCASL showed a good to excellent test-retest repeatability and potential of higher resolution (2 mm isotropic). The proposed technique also significantly improved SNR when compared to the same sequence at 3T and simultaneous multislice TFL-pCASL at 7T. By combining a new set of labeling parameters, OPTIM BS pulse, and accelerated 3D TFL readout, we achieved high resolution pCASL at 7T with whole-cerebrum coverage, detailed perfusion and anatomical information without distortion, and sufficient SNR.
Dynamic B field shimming for improving pseudo-continuous arterial spin labeling at 7 T.
Ji Y, Woods J, Li H, Okell T Magn Reson Med. 2024; 93(4):1674-1689.
PMID: 39642063 PMC: 11782713. DOI: 10.1002/mrm.30387.
Assessing Cerebral Microvascular Volumetric Pulsatility with High-Resolution 4D CBV MRI at 7T.
Guo F, Zhao C, Shou Q, Jin N, Jann K, Shao X medRxiv. 2024; .
PMID: 39281763 PMC: 11398588. DOI: 10.1101/2024.09.04.24313077.
Shao X, Guo F, Kim J, Ress D, Zhao C, Shou Q medRxiv. 2024; .
PMID: 39040201 PMC: 11261924. DOI: 10.1101/2024.04.01.24305167.
Wang K, Ju L, Song Y, Blair L, Xie K, Liu C Magn Reson Med. 2024; 92(4):1456-1470.
PMID: 38748853 PMC: 11262991. DOI: 10.1002/mrm.30134.