» Articles » PMID: 37362614

Enhanced Extraction of Blood and Tissue Time-Activity Curves in Cardiac Mouse FDG PET Imaging by Means of Constrained Nonnegative Matrix Factorization

Overview
Publisher Wiley
Specialty Radiology
Date 2023 Jun 26
PMID 37362614
Authors
Affiliations
Soon will be listed here.
Abstract

We propose an enhanced method to accurately retrieve time-activity curves (TACs) of blood and tissue from dynamic 2-deoxy-2-[F]fluoro-D-glucose ([F]FDG) positron emission tomography (PET) cardiac images of mice. The method is noninvasive and consists of using a constrained nonnegative matrix factorization algorithm (CNMF) applied to the matrix () containing the intensity values of the voxels of the left ventricle (LV) PET image. CNMF factorizes into nonnegative matrices and , respectively, representing the physiological factors (blood and tissue) and their associated weights, by minimizing an extended cost function. We verified our method on 32 C57BL/6 mice, 14 of them with acute myocardial infarction (AMI). With CNMF, we could break down the mouse LV into myocardial and blood pool images. Their corresponding TACs were used in kinetic modeling to readily determine the [F]FDG influx constant () required to compute the myocardial metabolic rate of glucose. The calculated values using CNMF for the heart of control mice were in good agreement with those published in the literature. Significant differences in values for the heart of control and AMI mice were found using CNMF. The values of the elements of agreed well with the LV structural changes induced by ligation of the left coronary artery. CNMF was compared with the recently published method based on robust unmixing of dynamic sequences using regions of interest (RUDUR). A clear improvement of signal separation was observed with CNMF compared to the RUDUR method.

Citing Articles

Accurate image derived input function in [F]SynVesT-1 mouse studies using isoflurane and ketamine/xylazine anesthesia.

Miranda A, Bertoglio D, Staelens S, Verhaeghe J EJNMMI Phys. 2023; 10(1):78.

PMID: 38052966 PMC: 10697927. DOI: 10.1186/s40658-023-00599-8.

References
1.
Wu H, Kreissl M, Schelbert H, Ladno W, Prins M, Shoghi-Jadid K . First-Pass Angiography in Mice Using FDG-PET: A Simple Method of Deriving the Cardiovascular Transit Time Without the Need of Region-of-Interest Drawing. IEEE Trans Nucl Sci. 2015; 52(5):1311-1315. PMC: 4608538. DOI: 10.1109/TNS.2005.858239. View

2.
Locke L, Berr S, Kundu B . Image-derived input function from cardiac gated maximum a posteriori reconstructed PET images in mice. Mol Imaging Biol. 2010; 13(2):342-7. PMC: 3036775. DOI: 10.1007/s11307-010-0347-4. View

3.
Lutgens E, Daemen M, de Muinck E, Debets J, Leenders P, Smits J . Chronic myocardial infarction in the mouse: cardiac structural and functional changes. Cardiovasc Res. 1999; 41(3):586-93. DOI: 10.1016/s0008-6363(98)00216-8. View

4.
Laforest R, Sharp T, Engelbach J, Fettig N, Herrero P, Kim J . Measurement of input functions in rodents: challenges and solutions. Nucl Med Biol. 2005; 32(7):679-85. DOI: 10.1016/j.nucmedbio.2005.06.012. View

5.
Bergeron M, Cadorette J, Tetrault M, Beaudoin J, Leroux J, Fontaine R . Imaging performance of LabPET APD-based digital PET scanners for pre-clinical research. Phys Med Biol. 2014; 59(3):661-78. DOI: 10.1088/0031-9155/59/3/661. View