Effects of Postmortem Storage by Freezing on Ligament Tensile Behavior

Overview
Journal J Biomech
Specialty Physiology
Date 1986 Jan 1
PMID 3733765
Citations 99
Authors
Affiliations
Soon will be listed here.
Abstract

The purpose of this study is to examine the effect of prolonged postmortem freezing storage (between 1 1/2 and 3 months at -20 degrees C) on the structural properties of the medial collateral ligament (MCL)-bone complex as well as the mechanical properties of the MCL substance from the rabbit knee. Tensile testing of the femur-MCL-tibia specimen was performed and no statistically significant changes were noted between the fresh and stored samples in terms of the cyclic stress relaxation, the load-deformation characteristics, as well as the load, deformation and energy absorbing capability at failure. The area of hysteresis of the stored samples was significantly reduced in the first few cycles, however. The mechanical properties of the MCL substance, as represented by the stress-strain curves, tensile strength and ultimate strain also did not change following storage. We conclude, therefore, proper and careful storage by freezing would have little or no effect on the biomechanical properties of the ligaments.

Citing Articles

Smaller Width Quadriceps Tendon Grafts Maintain Advantageous Biomechanical Properties for ACL Reconstruction.

Lee R, Voinier S, McCarthy C, Colantonio D, Gee S, Tucker C Orthop J Sports Med. 2025; 13(2):23259671251318014.

PMID: 39968412 PMC: 11833892. DOI: 10.1177/23259671251318014.


The importance of the posterior osteoligamentous complex of the lumbar spine: dogma changing biomechanical insights.

Jokeit M, Cornaz F, Schader J, Harshbarger C, Calek A, Jecklin S Eur Spine J. 2025; .

PMID: 39912946 DOI: 10.1007/s00586-025-08690-7.


Effect of Age on the Biomechanical Properties of Porcine LCL.

Singh N, Trajkovski J, Rodriguez Matas J, Kunc R Bioengineering (Basel). 2025; 12(1).

PMID: 39851279 PMC: 11762344. DOI: 10.3390/bioengineering12010005.


Evaluation of the Mechanical Behavior of the Patellar and Semitendinosus Tendons Using Supersonic Shear-wave Imaging (SSI) Elastography and Tensile Tests.

Fontenelle A, Mannarino P, Oliveira L, Menegaldo L, de Souza S, Fontenelle C Rev Bras Ortop (Sao Paulo). 2024; 59(4):e556-e563.

PMID: 39239578 PMC: 11374394. DOI: 10.1055/s-0044-1788290.


Biomechanical characteristics of the meniscocapsular junction of the posterior segment of the medial meniscus.

Nicolas Q, Samargandi R, Calloch S, Dubrana F, Gunepin F, Di Francia R Eur J Orthop Surg Traumatol. 2024; 34(6):2915-2923.

PMID: 38809423 DOI: 10.1007/s00590-024-03987-7.