» Articles » PMID: 37325121

A Simple and Fast Flow Injection Amperometry for the Determination of Methimazole in Pharmaceutical Preparations Using an Unmodified Boron-doped Diamond Electrode

Overview
Journal ADMET DMPK
Specialty Pharmacology
Date 2023 Jun 16
PMID 37325121
Authors
Affiliations
Soon will be listed here.
Abstract

In this work, an automated flow injection analysis (FIA) connected to a boron-doped diamond electrode (BDDE) was originally developed for the analysis of methimazole in pharmaceutical preparations. At a modification-free BDDE, methimazole was easilly oxidized. For the analysis of the mechanisms occurring at the electrode surface, cyclic voltammetry was employed to evaluate the impact of fundamental experimental parameters, such as pH and scan rate, on the BDDE response. For the quantitative detection, the FIA amperometric approach was constructed and used as a fast and sensitive method. The suggested approach provided a broad linear range of 0.5-50 μmol/L and a low detection limit of 10 nmol/L (signal-to-noise ratio = 3). Furthermore, the BDDE was successfully utilized to quantify methimazole in genuine samples from a variety of medicines, and its performance remained steady after more than 50 tests. The findings of amperometric measurements exhibit excellent repeatability, with relative standard deviations of less than 3.9 and 4.7 % for intra-day and inter-day, respectively. The findings indicated that, compared with traditional approaches, the suggested method has the following advantages: quick analysis time, simplicity, highly sensitive output, and no need for complicated operational processes.

Citing Articles

Fast and simple voltammetric sensing of avanafil in the pharmaceutical formulation by using unmodified boron-doped diamond electrode.

Ali H, Barzani H, Yardim Y ADMET DMPK. 2024; 12(3):529-542.

PMID: 39091902 PMC: 11289509. DOI: 10.5599/admet.2357.


An electrochemical sensing platform based on a modified carbon paste electrode with graphene/CoO nanocomposite for sensitive propranolol determination.

Karami-Kolmoti P, Zaimbashi R ADMET DMPK. 2023; 11(2):227-236.

PMID: 37325122 PMC: 10262224. DOI: 10.5599/admet.1705.


Voltammetric determination of hydrochlorothiazide at a modified carbon paste electrode with polypyrrole nanotubes.

Mohammadnavaz A, Garkani-Nejad F ADMET DMPK. 2023; 11(2):293-302.

PMID: 37325111 PMC: 10262231. DOI: 10.5599/admet.1706.

References
1.
Soledad Garcia M, Albero M, Sanchez-Pedreno C, Tobal L . Kinetic determination of carbimazole, methimazole and propylthiouracil in pharmaceuticals, animal feed and animal livers. Analyst. 1995; 120(1):129-33. DOI: 10.1039/an9952000129. View

2.
Norouzi P, Gupta V, Larijani B, Ganjali M, Faridbod F . A new Methimazole sensor based on nanocomposite of CdS NPs-RGO/IL-carbon paste electrode using differential FFT continuous linear sweep voltammetry. Talanta. 2014; 127:94-9. DOI: 10.1016/j.talanta.2014.03.061. View

3.
Pungjunun K, Chaiyo S, Jantrahong I, Nantaphol S, Siangproh W, Chailapakul O . Anodic stripping voltammetric determination of total arsenic using a gold nanoparticle-modified boron-doped diamond electrode on a paper-based device. Mikrochim Acta. 2018; 185(7):324. DOI: 10.1007/s00604-018-2821-7. View

4.
Yazhen W . Electrochemical determination of methimazole based on the acetylene black/chitosan film electrode and its application to rat serum samples. Bioelectrochemistry. 2011; 81(2):86-90. DOI: 10.1016/j.bioelechem.2011.04.001. View

5.
Wang A, Zhang L, Zhang S, Fang Y . Determination of thiols following their separation by CZE with amperometric detection at a carbon electrode. J Pharm Biomed Anal. 2000; 23(2-3):429-36. DOI: 10.1016/s0731-7085(00)00326-5. View