» Articles » PMID: 37316428

CMUT Technology Developments

Overview
Journal Z Med Phys
Specialty Radiology
Date 2023 Jun 14
PMID 37316428
Authors
Affiliations
Soon will be listed here.
Abstract

Capacitive micromachined ultrasonic transducer (cMUT) technology has steadily advanced since its advent in the mid-1990's. Though cMUTs have not supplanted piezoelectric transducers for medical ultrasound imaging to date, researchers and engineers are continuing to improve cMUTs and leverage unique cMUT characteristics toward new applications. While not intended to be an exhaustive review of every aspect of cMUT state-of-the-art, this article provides a brief overview of cMUT benefits, challenges, and opportunities, as well as recent progress in cMUT research and translation.

Citing Articles

Radiation Impedance of Rectangular CMUTs.

Khorassany S, Dew E, Rahim Sobhani M, Zemp R Sensors (Basel). 2024; 24(17).

PMID: 39275732 PMC: 11398137. DOI: 10.3390/s24175823.


Therapeutic ultrasound transducer technology and monitoring techniques: a review with clinical examples.

Lafond M, Payne A, Lafon C Int J Hyperthermia. 2024; 41(1):2389288.

PMID: 39134055 PMC: 11375802. DOI: 10.1080/02656736.2024.2389288.


CMUT as a Transmitter for Microbubble-Assisted Blood-Brain Barrier Opening.

Kilinc M, Pakdaman Zangabad R, Arvanitis C, Degertekin F IEEE Trans Ultrason Ferroelectr Freq Control. 2024; 71(8):1042-1050.

PMID: 38905098 PMC: 11403385. DOI: 10.1109/TUFFC.2024.3417818.


Application of Through Glass Via (TGV) Technology for Sensors Manufacturing and Packaging.

Yu C, Wu S, Zhong Y, Xu R, Yu T, Zhao J Sensors (Basel). 2024; 24(1).

PMID: 38203033 PMC: 10781294. DOI: 10.3390/s24010171.

References
1.
Greenlay B, Zemp R . Fabrication of Linear Array and Top-Orthogonal-to-Bottom Electrode CMUT Arrays With a Sacrificial Release Process. IEEE Trans Ultrason Ferroelectr Freq Control. 2017; 64(1):93-107. DOI: 10.1109/TUFFC.2016.2620425. View

2.
Feinstein S, Coll B, Staub D, Adam D, Schinkel A, Ten Cate F . Contrast enhanced ultrasound imaging. J Nucl Cardiol. 2009; 17(1):106-15. DOI: 10.1007/s12350-009-9165-y. View

3.
Satir S, Zahorian J, Degertekin F . A large-signal model for CMUT arrays with arbitrary membrane geometry operating in non-collapsed mode. IEEE Trans Ultrason Ferroelectr Freq Control. 2013; 60(11):2426-39. PMC: 4029428. DOI: 10.1109/TUFFC.2013.6644745. View

4.
Ferrara K, Pollard R, Borden M . Ultrasound microbubble contrast agents: fundamentals and application to gene and drug delivery. Annu Rev Biomed Eng. 2007; 9:415-47. DOI: 10.1146/annurev.bioeng.8.061505.095852. View

5.
Bayram B, Yaralioglu G, Kupnik M, Ergun A, Oralkan O, Nikoozadeh A . Dynamic analysis of capacitive micromachined ultrasonic transducers. IEEE Trans Ultrason Ferroelectr Freq Control. 2006; 52(12):2270-5. DOI: 10.1109/tuffc.2005.1563269. View