» Articles » PMID: 37308256

A Quality Improvement Initiative to Reduce Central Line-associated Bloodstream Infections in a Neonatal Intensive Care Unit in a Low-and-middle-income Country

Overview
Journal BMJ Open Qual
Specialty Health Services
Date 2023 Jun 12
PMID 37308256
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Premature and sick neonates in the neonatal intensive care unit (NICU) are in need of central lines placing them at high risk of contracting a central line-associated bloodstream infection (CLABSI). CLABSI extends length of stay to 10-14 days post negative cultures and increases morbidity, use of multiple antibiotics, mortality and hospital cost. To reduce CLABSI rate at the American University of Beirut Medical Center NICU, the National Collaborative Perinatal Neonatal Network developed a quality improvement project to reduce CLABSI rate by 50% over a 1-year period and to sustain reduced CLABSI rate.

Methods: Central line insertion and maintenance bundles were implemented for all infants admitted to the NICU necessitating central lines placement. Bundles included hand washing, wearing protective material and sterile drapes during central lines insertion and maintenance.

Results: CLABSI rate decreased by 76% from 4.82 (6 infections; 1244 catheter days) to 1.09 (2 infection; 1830 catheter days) per 1000 CL days after 1 year. Following the bundles' success in reducing CLABSI rate, they were incorporated permanently to NICU standard procedure and bundle checklists were added to the medical sheets. CLABSI rate was maintained at 1.15 per 1000 CL days during the second year. It then decreased to 0.66 per 1000 CL days in the third year before reaching zero in the fourth year. In total, zero CLABSI rate was sustained for 23 consecutive months.

Conclusion: Reducing CLABSI rate is necessary to improving newborn quality of care and outcome. Our bundles were successful in drastically reducing and sustaining a low CLABSI rate. It was even successful in achieving a zero CLABSI unit for 2 years.

References
1.
Rosenthal V . Central line-associated bloodstream infections in limited-resource countries: a review of the literature. Clin Infect Dis. 2009; 49(12):1899-907. DOI: 10.1086/648439. View

2.
Steiner M, Langgartner M, Cardona F, Waldhor T, Schwindt J, Haiden N . Significant Reduction of Catheter-associated Blood Stream Infections in Preterm Neonates After Implementation of a Care Bundle Focusing on Simulation Training of Central Line Insertion. Pediatr Infect Dis J. 2015; 34(11):1193-6. DOI: 10.1097/INF.0000000000000841. View

3.
OGrady N, Alexander M, Burns L, Dellinger E, Garland J, Heard S . Summary of recommendations: Guidelines for the Prevention of Intravascular Catheter-related Infections. Clin Infect Dis. 2011; 52(9):1087-99. PMC: 3106267. DOI: 10.1093/cid/cir138. View

4.
Hussain A, Ahmed A, Arbab S, Ariff S, Ali R, Demas S . CLABSI reduction using evidence based interventions and nurse empowerment: a quality improvement initiative from a tertiary care NICU in Pakistan. Arch Dis Child. 2020; 106(4):394-400. DOI: 10.1136/archdischild-2019-318779. View

5.
Rosenthal V, Duenas L, Sobreyra-Oropeza M, Ammar K, Navoa-Ng J, de Casares A . Findings of the International Nosocomial Infection Control Consortium (INICC), part III: effectiveness of a multidimensional infection control approach to reduce central line-associated bloodstream infections in the neonatal intensive care units of.... Infect Control Hosp Epidemiol. 2013; 34(3):229-37. DOI: 10.1086/669511. View