Rapid Estimation of Insertional Length of Umbilical Catheters in Newborns

Overview
Journal Am J Dis Child
Specialty Pediatrics
Date 1986 Aug 1
PMID 3728405
Citations 29
Authors
Affiliations
Soon will be listed here.
Abstract

To determine the neonatal body measurement that best predicts insertional umbilical catheter lengths, we studied two commonly used parameters--shoulder-to-umbilicus length and total body length--and two new parameters--suprasternal notch-pubic symphysis length and birth weight (BW)--on 43 umbilical artery (UA) and ten umbilical vein (UV) catheterizations. The new parameters showed better correlations than the currently used ones. The BW variable, with the highest coefficient of correlation among all four parameters, was applied prospectively in 25 UA and 16 UV catheter insertions. All catheter tips thus placed were found to be in acceptable positions. Although any one of the four parameters can be used clinically, we prefer the BW parameter for its reliability, reproducibility, and ability to be estimated in emergency settings. The modified regression (estimating) equations utilizing BW are as follows: UA catheter length = 3 X BW + 9; UV catheter length = 1/2 X UA line calculation + 1, in which lengths are measured in centimeters and BW is measured in kilograms.

Citing Articles

Real-time ultrasound for umbilical venous catheter insertion in neonates- a systematic review and meta-analysis.

Anne R, Rahiman E, Aradhya A Ultrasound J. 2025; 17(1):4.

PMID: 39804534 PMC: 11730037. DOI: 10.1186/s13089-025-00406-8.


Comparative analysis of formulae for umbilical venous catheterization depth based on birth weight.

Luo J, Zheng X, Yang Z, Li K, Chen L, Hei M Pediatr Investig. 2024; 8(4):265-270.

PMID: 39720282 PMC: 11664533. DOI: 10.1002/ped4.12451.


Real-time ultrasound to assess the umbilical catheter position in neonates: a randomized, controlled trial.

Ponin L, Ruangkit C, Ruangwattanapaisarn N, Nuntnarumit P J Perinatol. 2024; 45(2):235-241.

PMID: 39379732 PMC: 11825353. DOI: 10.1038/s41372-024-02128-6.


Reducing umbilical catheter migration rates by using a novel securement device.

Perl J, Crabtree-Beach T, Olyaei A, Hedges M, Jordan B, Scottoline B J Perinatol. 2024; 44(9):1359-1364.

PMID: 38521880 PMC: 11379623. DOI: 10.1038/s41372-024-01943-1.


Umbilical Vein Calcification Associated with Double-Lumen Catheter Malpositioning in an Extremely Low-Birth-Weight Infant.

Yamamoto T, Iijima S Pediatr Rep. 2024; 16(1):69-76.

PMID: 38251316 PMC: 10801626. DOI: 10.3390/pediatric16010007.